측정 단위:
* special requirements. EA
MRC:
The number of prime movers incorporated in the unit.AAXH
Prime Mover Quantity:
1
MRC:
Indicates the type of current whether alternating,direct,or both.ACDC
Current Type:
Ac
MRC:
The name and number of those parts furnished with the item of supply that have not been specified elsewhere.ACSY
Furnished Items And Quantity:
1 motor controller
MRC:
The environmental elements or conditions that an item is designed or protected to resist or withstand satisfactorily.ADZC
Environmental Protection:
Splashtight
MRC:
Indicates the type of prime mover included with the unit.AKDJ
Prime Mover Type:
Electric motor
MRC:
Indicates the type of inclosure provided to coat,cover,protect,or encase the item.AKNA
Inclosure Type:
Fully enclosed
MRC:
The working period under which the item was designed to operate.AKPS
Duty Cycle:
Intermittent
MRC:
The means used to operate the item.APHE
Operation Method:
Powered
MRC:
An indication of the capstan spool/s/ mounting position.ATWG
Capstan Spool Mounting Position:
Horizontal
MRC:
The design of the capstan spool surface.ATWJ
Capstan Spool Surface Design:
Plain
MRC:
The number of capstan spools included.ATWK
Capstan Spool Quantity:
2
MRC:
The total load the item is capable of moving at selected speeds and the drum location.ATWN
Load Limit At Selected Speed And Drum Location:
3000.0 pounds single speed first drum and 3000.0 pounds second speed first drum and 3000.0 pounds single speed second drum
MRC:
The distance that the item will move per minute,per specific measurement scale.ATWP
Travel Rate Per Minute:
60.0 feet and 120.0 feet
MRC:
The means by which the braking action is applied.ATWS
Braking Method:
Electric
MRC:
The power required to start and operate the item at rated capacity.ATYG
Power Requirement Rating:
30.00 horsepower
Overall Length And Location:
12.000 inches first spool and 12.000 inches second spool
Err Default:
Err default and err default
Smallest Diameter And Location:
15.125 inches first spool and 15.125 inches second spool
MRC:
The total electrical voltage.ELEC
Voltage In Volts:
440.0
MRC:
The number of alternating current phases.FAAZ
Phase:
Three
MRC:
The cycles per second /hertz/ of the alternating current.FREQ
Frequency In Hertz:
60.0
MRC:
The specification,standard,drawing,or similar instrument that specifies environmental and performance requirements or test conditions under which an item is tested and establishes acceptable limits within which the item must conform identified by an alphabetic and/or numeric reference number. includes the commercial and government entity (cage) code of the entity controlling the instrument.TEST
Test Data Document:
81349-mil-w-15802 specification (includes engineering type bulletins, brochures, etc., that reflect specification type data in specification format; excludes commercial catalogs, industry directories, and similar trade publications, reflecting general type data on certain environmental and performance requirements and test conditions that are shown as "typical", "average", "", etc.).