TXT
				
				
					묘사:
				
				
					Variable Attenuator				
			 
			
										
					
						MRC:
						The primary application for which the item is designed.AAFS
					 
					
						Application Design:
					
					
						Transmission line					
				 
							
					
						MRC:
						The style designation indicating the configuration that most nearly corresponds to the appearance of the body.AAQL
					 
					
						Body Style:
					
					
						Coaxial type					
				 
							
					
						MRC:
						The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
					 
					
						Overall Length:
					
					
						3.688 inches 					
				 
							
					
						MRC:
						The distance measured in a straight line from the bottom to the top of an item.ABKW
					 
					
						Overall Height:
					
					
						2.609 inches 					
				 
							
					
						MRC:
						An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
					 
					
						Overall Width:
					
					
						1.875 inches 					
				 
							
					
						MRC:
						The length of a straight line which passes through the center of a shaft,and terminates at the circumference.ABWV
					 
					
						Shaft Diameter:
					
					
						0.250 inches 					
				 
							
					
						MRC:
						A measurement of the longest dimension of the shaft,in distinction from width.ABXF
					 
					
						Shaft Length:
					
					
						0.750 inches 					
				 
							
					
						MRC:
						The distance between mounting facility centers.AEJN
					 
					
						Distance Between Mounting Facility Centers:
					
					
						1.125 inches 					
				 
							
					
						MRC:
						The ratio of the maximum to the minimum amplitude of pressure /voltage/ measured along the path of the waves.AHTW
					 
					
						Voltage Standing Wave Ratio:
					
					
						1.20					
				 
							
					
						MRC:
						A letter or group of letters used to designate the particular coaxial connector series.AHUC
					 
					
						Coaxial Connector Series Designation:
					
					
						Tnc					
				 
							
					
						MRC:
						The amount of electrical energy that can be dissipated.AJDB
					 
					
						Power Rating:
					
					
						100.0 milliwatts average					
				 
							
					
						MRC:
						A designation distinguishing one group of screw thread diameter-pitch combinations from another by the number of threads per measurement scale for a specific diameter on the mounting facility.AKEJ
					 
					
						Mounting Facility Screw Thread Series Designator:
					
					
						Unc					
				 
							
					
						MRC:
						The overall limits of decrease of the amplitude ratio of a signal between the input and output of the item,expressed in decibels.ASYD
					 
					
						Overall Attenuation Range In Decibels:
					
					
						+0.0/+70.0					
				 
							
					
						MRC:
						The means by which the attenuation can be varied from the minimum to the maximum setting.ASYF
					 
					
						Attenuation Variation Method:
					
					
						Stepped					
				 
							
					
						MRC:
						The number of intervals at which the item can be set.ASYG
					 
					
						Step Position Quantity:
					
					
						7					
				 
							
					
						MRC:
						The amount of attenuation between adjacent steps,expressed in decibels.ASYH
					 
					
						Attenuation Per Step In Decibels:
					
					
						10.0					
				 
							
					
						MRC:
						Indicates the type and number of facilities by which the item is mounted.AXHR
					 
					
						Mounting Facility Type And Quantity:
					
					
						2 threaded hole					
				 
							
					
						MRC:
						The minimum and maximum cyclic changes,per unit of time,for which an item is rated.BNGR
					 
					
						Frequency Range:
					
					
						Between 0.000 hertz and 1.000 megahertz 					
				 
							
					
						MRC:
						The overall limits of permissible variation in the attenuation accuracy from the nominal value at a specified frequency rating or range,expressed in decibels.BQNR
					 
					
						Overall Attenuation Accuracy In Decibels:
					
					
						-0.60/+0.60					
				 
							
					
						MRC:
						The number of mounting threads on the item measured on a line parallel to the thread axis,including incomplete threads.CGGK
					 
					
						Mounting Thread Quantity:
					
					
						32 per inch					
				 
							
					
						MRC:
						Indicates the type and number of facilities for adjusting the item.CQTQ
					 
					
						Adjustment Device Type And Quantity:
					
					
						1 shaft					
				 
							
					
						MRC:
						The general configuration and relative position of the facilities provided for mounting the item.CQYJ
					 
					
						Mounting Facility Pattern:
					
					
						Two position in-line					
				 
							
					
						MRC:
						Indicates the type of shaft included on the item.CRSJ
					 
					
						Shaft Type:
					
					
						Round					
				 
							
					
						MRC:
						The nominal length of a straight line which passes through the center of a coaxial cylinder which would bound the crest of an external thread or the root of an internal thread.CRYY
					 
					
						Mounting Facility Screw Thread Diameter:
					
					
						0.164 inches					
				 
							
					
						MRC:
						The total opposition (resistive and reactive) to the flow of alternating current,expressed in ohms.CTGG
					 
					
						Impedance Rating In Ohms:
					
					
						50.0 input-output					
				 
							
					
						MRC:
						Indicates the type and number of terminals for providing electrical connection.TTQY
					 
					
						Terminal Type And Quantity:
					
					
						2 connector,  coaxial,  female