부품 정보
Breathing air pump unit; hd-409/fps-20; fig 290-385, t.O.31p5-2fps20-4, tech manual illustrated part breakdown, radar sets an/fps-20 series, pg 789
TXT
묘사:
Rotary Compressor Unit
MRC:
The number of compressors incorporated in the unit.AAXG
Compressor Quantity:
1
MRC:
The media the machine is designed to compress.AAXK
Gas For Which Designed:
Air
MRC:
The rated capacity of gas delivered by the last stage of compression.AAXL
Discharge Flow Rate:
9.000 cubic feet per minute
MRC:
The gage pressure of gas delivered by the last stage of compression. referred to as condensing pressure for refrigeration compressors.AAXM
Discharge Pressure:
9.000 pounds per square inch gage
MRC:
The design of the system necessary to maintain the required operating temperature of an item and discharge temperature of the compressed gases.AAXP
Cooling System Design:
Single
MRC:
The cooling medium used to maintain the required operating temperature of the compressed gases.AAXQ
Compressed Gas Cooling Medium:
Air
MRC:
The cooling medium used to maintain the required operating temperature of the compressor.AAXR
Compressor Cooling Medium:
Air
MRC:
The cooling medium used to maintain the required operating temperature of the prime mover.AAXS
Prime Mover Cooling Medium:
Air
MRC:
Indicates the type of mount utilized to support the item.AAXX
Mounting Type:
Base
MRC:
The mechanical action by which compression takes place.AAYB
Rotary Compressor Design:
Sliding vane
MRC:
The number of stages incorporated in the item.AAYD
Stage Quantity:
1
MRC:
The number of intake connections included on the item.AAYT
Intake Connection Quantity:
1
MRC:
The number of discharge connections included on the item.AAYV
Discharge Connection Quantity:
1
MRC:
Indicates the type of discharge connection included on the item.AAYW
Discharge Connection Type:
Threaded male
MRC:
Indicates the type of prime mover included with the unit.AKDJ
Prime Mover Type:
Electric motor
MRC:
Indicates the type and amount of electrical flow at which the item is designed to operate,expressed in amperes.CQJY
Current Type And Rating In Amps:
5.2 ac
MRC:
The total electrical voltage,expressed in volts,and the type of current whether alternating or direct.CSBH
Voltage In Volts And Current Type:
208.0 ac
MRC:
The number of alternating current phases.FAAZ
Phase:
Three
MRC:
Those unusual or unique characteristics or qualities of an item not covered in the other requirements and which are determined to be essential for identification.FEAT
Special Features:
Hd-409/fps-20; function, power driven rotary compressor; reference data, fig 290-385, t.O. 31p6-2fps20-4, technical manual, illustrated parts breakdown, radar sets an/fps-20 series, pg 789
MRC:
The cycles per second /hertz/ of the alternating current.FREQ
Frequency In Hertz:
60.0