부품 정보
O-315/fps-20; function, radio frequency oscillator; reference data, fig 154-2, t.O. 31p6-2fps20-4, technical manual, illustrated parts breakdown, radar sets an/fps-20, pg 401
TXT
묘사:
Noncrystal Controlled Oscillator
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
23.800 inches
MRC:
The distance measured in a straight line from the bottom to the top of an item.ABKW
Overall Height:
7.700 inches
MRC:
An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
Overall Width:
9.680 inches
MRC:
The national stock number or the identification information of the end equipment for which the item is a part.AGAV
End Application:
Anfps-20, rf oscillators mounting panel
MRC:
The style designation indicating the configuration that most nearly corresponds to the basic appearance of the item.AGTA
Basic Shape Style:
Rectangular or square
MRC:
A designation assigned to the item for purpose of ready identification.AJKH
Identification Designator:
0.315/fps20-80058
MRC:
Indicates the type of circuit construction provided in the item.BHSX
Circuit Construction Type:
Solid state
MRC:
The portion of the frequency spectrum at which an item is designed to receive or transmit signal power.BHTB
Frequency Per Channel:
1270.0 megahertz operating channel and 1330.0 megahertz operating channel
MRC:
The rated average power for each channel.BHTJ
Average Power Rating Per Channel:
200.0 milliwatts output
MRC:
The cycles per second /hertz/ of the operating alternating current.BJBQ
Operating Ac Frequency In Hertz:
60.0 single voltage
MRC:
The value(s) of the potential supplied from an exterior direct current source to operate the item,expressed in volts.BKFB
External Dc Operating Voltage In Volts:
6.3 2nd voltage err-100
MRC:
The value(s) of the potential supplied from an exterior direct current source to operate the item,expressed in volts.BKFB
External Dc Operating Voltage In Volts:
-250.0 1st voltage err-100
MRC:
The value(s) of the potential supplied from an exterior alternating current source to operate the item,expressed in volts.BKFC
External Ac Operating Voltage In Volts:
120.0 single voltage
MRC:
The number of alternating current phases.FAAZ
Phase:
Single