TXT
묘사:
Fluid Pressure Regulating Valve
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the body.AAQL
Body Style:
Angle
MRC:
A narrative description of the type of end connection.ACKM
First End Connection Type:
Threaded internal pipe
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the end.ACKN
First End Style Designator:
Plain
MRC:
Indicates whether or not the second end is identical to the first end.ACLR
Second End Relationship With First End:
Identical
MRC:
The part that controls the flow through the item.ADQU
Flow Control Device:
Disk
MRC:
The number of end connections included in the item.ADQZ
End Connection Quantity:
2
MRC:
The means of providing resistance to the media passing through a valve,whereby the valve is actuated to regulate the flow.AEVR
Valve Loading Method:
Spring
MRC:
The maximum pressure of the media on the inlet side at which an item is designed to operate.AEVZ
Maximum Inlet Pressure Rating:
5000.0 pounds per square inch
MRC:
The rated variance of the outlet pressure from the set pressure.AEWB
Outlet Pressure Accuracy Rating:
150.000 pounds per square inch
MRC:
A value which expresses the degree of heat or cold as applied to the operation,or limitation of operation,of an item.AZKQ
Tempurature Rating:
120.0 degrees fahrenheit