부품 번호 R1001-1A

Control Transformer Synchro

가격 및 가용성

이 NSN의 현재 가격 및 가용성에 대해 이 양식을 제출하십시오.
부품 번호:
양:
이메일 주소:
전화:
참조:
회사:
이름:

우리는 귀하의 정보를 누구에게도 공유하거나 판매하지 않습니다.
사생활 | 용어

All major credit cards accepted as well as gov. p-cards
부품 번호
비무장화
수명
UOM
NIIN
부품 번호:
r1001-1a
비무장화:
No
수명:
측정 단위:
NIIN:
006465487
NSN
국가 주식 번호:
5990-00-646-5487 5990006465487
TXT
묘사:
Control Transformer Synchro
INC
INC
아이템 이름 코드:
15289
MRC:
The basic material of which the body is fabricated.AAFZ
Body Material:
Steel, stainless
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
1.2800 inches
MRC:
The length of a straight line which passes through the center of a flange,and terminates at the circumference.ABKK
Flange Diameter:
0.7500 inches
MRC:
The maximum permissible temperature increase in the item as a result of its operation under normal conditions.AHCG
Maximum Tempurature Rise:
3.0 degrees celsius
MRC:
The value of the primary excitation voltage for which the stator is rated,expressed in volts.AJSN
Stator Input Voltage Rating In Volts:
11.8
MRC:
The value of the primary excitation current for which the stator is rated,with rotor /secondary/ circuit open.AJSP
Stator Input Current Rating:
145.0 amperes
MRC:
The value of the primary /electrical/ excitation power for which the stator is rated.AJSQ
Stator Input Electrical Power Rating:
0.3 watts
MRC:
The cycles per second /hertz/ of the alternating current.AJSS
Frequency In Hertz:
400.0
MRC:
The magnitude part /z/ of the stator impedance with the rotor open /zso/,expressed in ohms.AJTJ
Zso Impedance Magnitude In Ohms:
79.00
MRC:
The angle part /o/ of the stator impedance with the rotor open /zso/,expressed in degrees.AJTK
Zso Impedance Angle In Deg:
73.00
MRC:
The opposition that the rotor offers to the flow of the direct current,expressed in ohms.AJTS
Rotor Dc Resistance In Ohms:
118.00
MRC:
The opposition that the stator offers to the flow of direct current,expressed in ohms.AJTT
Stator Dc Resistance In Ohms:
24.50
MRC:
The difference between the phase time of two or more voltages or currents of the same frequency,at the same instant of time,expressed in degrees.AJVF
Phase Shift Angle In Deg:
13.500 output to input
MRC:
The maximum voltage,without harmonics,induced in the secondary circuit at the null angle rotor position,expressed in millivolts per volt.AJVG
Maximum Fundamental Null Voltage In Millivolts Per Volt:
34.00 input
MRC:
The maximum voltage,including harmonics,induced in the secondary circuit at the null angle rotor position,expressed in millivolts per volt.AJVH
Maximum Total Null Voltage Output In Millivolts Per Volt:
53.00
MRC:
The limits of permissible deviation in angular arc error from electrical zero,expressed in minutes.AJVL
Electrical Error Angular Range In Minutes:
-5.0/+5.0
MRC:
The amount of rotary force that must be applied to the actuator to cause rotation,at minus 55 degrees celsius.AJVS
Actuator Friction Torque At Minus 55 Deg Celsius:
12.00 centimeter-grams
MRC:
The amount of rotary force that must be applied to the actuator to cause rotation,at plus 25 degrees celsius.AJVT
Actuator Friction Torque At Plus 25 Deg Celsius:
3.00 centimeter-grams
MRC:
Indicates the location of the terminal/s/ on the item.CQTM
Terminal Location:
Rear
MRC:
None.CQZS
Shaft Slot Depth:
0.0300 inches single shaft
MRC:
None.CRHN
Shaft Slot Width:
0.0250 inches single shaft
MRC:
Indicates the type of shaft included on the item.CRSJ
Shaft Type:
Round, slotted single shaft
MRC:
The ratio of the output voltage to the input voltage at maximum coupling.CSJY
Transformation Ratio:
2.203 stator to rotor
MRC:
Indicates the type and number of terminals for providing electrical connection.TTQY
Terminal Type And Quantity:
5 wire lead

{lang[cimilar]} Control Transformer Synchros

« Synchros and Resolvers {lang[catalog]}
지금 비교»