부품 정보
End thd des and size std-din thread no spot face; pressure range 0.3 to 3.4 bar
TXT
묘사:
Fluid Pressure Regulating Valve
MRC:
The basic material of which the body is fabricated.AAFZ
Body Material:
Zinc alloy
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the body.AAQL
Body Style:
Straight thru
MRC:
Items furnished as accessories which are not specified elsewhere.ABFF
Furnished Items:
Bonnet and nut
MRC:
The type of service with which the item is designed to be used.ACKL
Media For Which Designed:
Air
MRC:
A narrative description of the type of end connection.ACKM
First End Connection Type:
Threaded internal pipe
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the end.ACKN
First End Style Designator:
Plain
MRC:
The direction of the thread when viewed axially. a right-hand thread winds in a clockwise direction while a left-hand thread winds in a counterclockwise direction.ACLL
First End Thread Direction:
Right-hand
MRC:
Indicates whether or not the second end is identical to the first end.ACLR
Second End Relationship With First End:
Identical
MRC:
The element,compound,or mixture of which the seating surfaces are fabricated.ACSH
Seat Material:
Plastic, acetal
MRC:
The element,compound,or mixture of which the packing is fabricated.ADQT
Packing Material:
Rubber, buna-n
MRC:
The part that controls the flow through the item.ADQU
Flow Control Device:
Diaphragm
MRC:
The element,compound,or mixture of which the flow control device is fabricated.ADQV
Flow Control Device Material:
Rubber, buna-n
MRC:
The number of end connections included in the item.ADQZ
End Connection Quantity:
2
MRC:
Indicates the type of renewable seating ring in the item.ADZH
Renewable Seat Ring Type:
Pressed-in
MRC:
The means other than the end connection/s/ by which the item may be mounted.ADZJ
Mounting Facility:
Panel
MRC:
Indicates the basic design type used for regulating the item.AEVN
Regulation Type:
Automatic single stage
MRC:
The means of providing resistance to the media passing through a valve,whereby the valve is actuated to regulate the flow.AEVR
Valve Loading Method:
Spring
MRC:
An indication of whether or not a filter is included.AEWF
Filter:
Not included
MRC:
A value which expresses the degree of heat or cold as applied to the operation,or limitation of operation,of an item.AZKQ
Tempurature Rating:
Between -18.0 degrees celsius and 66.0 degrees celsius
MRC:
Characteristics or qualities of an item,not covered in any other requirement,which are considered essential information for one or more functions excluding nsn assignment.SUPP
Supplementary Features:
Compressed air service, non-relieving model w/o guage; ref data mfr specification nc-231