부품 정보
Part name assigned by controlling agency is; normally closed, 2 way with external pilot & vent diveter valve
TXT
묘사:
Directional Control Linear Valve
MRC:
The number of end connections included in the item.ADQZ
End Connection Quantity:
2
MRC:
The rated valve discharge capacity per unit of time.ADSY
Valve Discharge Flow Rate:
12.0 gallons per minute
MRC:
The national stock number or the identification information of the end equipment for which the item is a part.AGAV
End Application:
4820-01-518-2475 8 valve manifold assembly
MRC:
The means used to control the operation of the valve.AQLR
Valve Operation Method:
Automatic
MRC:
Indicates the type of connection/s/.AWLS
Connection Type:
Threaded external boss
MRC:
The number of threads on the item per linear inch measured on a line parallel to the thread axis.CMLP
Thready Qty Per Inch (tpi):
14
MRC:
The maximum pressure at which an item is rated to operate for each type of service with which an item may be used.CQCJ
Maximum Operating Pressure And Media For Which Designed:
6000.0 pounds per square inch oil, lubricating, diester base
MRC:
A designation that is used for the purpose of general identification of the thread.CQJX
Thread Size:
0.875 inches
MRC:
A rating which expresses the degree of heat or cold as applied to the operation,or limitation of operation,for each type of service with which an item may be used.CRWH
Maximum Operating Tempurature And Media For Which Designed:
210.0 degrees fahrenheit oil, lubricating, diester base
MRC:
The number of fl0w patterns provided.CYGY
Flow Pattern Quantity:
3
MRC:
The number of spools provided.CYHB
Spool Quantity:
1
MRC:
A designation distinguishing one group of thread diameter-pitch combinations from another by the number of threads per measurement scale for a specific diameter.THSD
Thread Series Designator:
Unf