부품 정보
Mode 1 operation calibrated for mil-j-5624 at a specific gravity of 0.7620 and mode 2 for mil-h-5606 at a specific gravity of 0.8220; frequency range 2.5/1450.0 hz ; pressure rated to 3000 psig, 19 psig pressure drop at flow; 303 stainless steel construction; 2 aluminum flow straighteners one upstream and one downstream; extended magnetic pickup; secondary ranges 175/75000 pph at an sg of 0.7620 or 125/21000 pph at a sg of 0.8220
TXT
묘사:
Rate Of Flow Transmitter
MRC:
The number of terminals for providing electrical connection to the item.AARA
Terminal Quantity:
2
MRC:
Indicates the type of terminals for providing electrical connection to the item.AARB
Terminal Type:
Captive screw
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
13.500 inches
MRC:
The distance measured in a straight line from the bottom to the top of an item.ABKW
Overall Height:
5.420 inches
MRC:
A measurement of the longest straight line across a circular cross-sectional plane.ADAV
Overall Diameter:
2.880 inches
MRC:
The means by which the item is actuated.AFLW
Actuation Method:
Angular mass momentum principle turbine actuated and magnet
MRC:
The national stock number or the identification information of the end equipment for which the item is a part.AGAV
End Application:
A/m99 mobile calibration van for jet engine test stand
MRC:
The number of electrical connections provided.ASKX
Electrical Connection Quantity:
1
MRC:
The identifying number assigned by the government agency or commercial organization controlling the electrical connection.ASKZ
Electrical Connection Identifying Number:
Pt02e-8-2p
MRC:
The number of mechanical connections provided.ASSB
Mechanical Connection Quantity:
2
MRC:
Designates the thread size,diameter,or the like,of the mechanical connection.ASSC
Mechanical Connection Size:
1.5 inch per and10050
MRC:
Indicates the type of mechanical connection/s/ provided.ASSD
Mechanical Connection Type:
Male flared tube
MRC:
The means of attaching the item.AXGY
Mounting Method:
Flange
MRC:
The minimum and maximum limits of measurement indicated by the item.BGNL
Measurement Range:
+0.5/+195.0 gallons per minute and +0.3/+50.0 gallons per minute