TXT
묘사:
Flow Rate Indicating Meter
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
7.000 inches
MRC:
The type of service with which the item is designed to be used.ACKL
Media For Which Designed:
Liquid
MRC:
A narrative description of the type of inlet connection.ACQW
Inlet Connection Type:
Threaded
MRC:
An indication of whether or not an integral safety device is included.AHZU
Integral Relief Valve:
Not included
MRC:
The name and number of parts supplied with the item which may be required for application.AKYD
Accessory Components And Quantity:
3-wire reed switch (8w 30a 120vac/100vdc) 1, ceramic magnet 1, housing 1, foam gasket 1, half-collar 2, mounting and hardware
MRC:
An indication of the type of meter.ANTH
Meter Type:
Piston/spring
MRC:
Indicates the design type of the item.APGF
Design Type:
Case
MRC:
Indicates the type of unit.APQB
Unit Type:
Mounted
MRC:
The number of scales on the item.APSJ
Scale Quantity:
1
MRC:
The structural characteristic of the item.ARQS
Construction:
Inclosed w/sight window
MRC:
A narrative description of the type of outlet connection.ARTH
Outlet Connection Type:
Threaded
MRC:
An indication of the marking(s) on the scale.ASTW
Scale Marking:
Liters per minute
MRC:
Indicates the type of scale.ATEQ
Scale Type:
Direct capacity reading
MRC:
The element,compound,or mixture of which the tube is fabricated,excluding any surface treatment.AWGJ
Tube Material:
Plastic
MRC:
The means of attaching the item.AXGY
Mounting Method:
Direct line
MRC:
An indication of whether or not a carrying handle is included.AXQG
Carrying Handle:
Not included
MRC:
The minimum and maximum markings on a dial scale.BHBY
Dial Scale Marking Range:
+0.0/+38.0
MRC:
An indication of whether or not a base(s) is included.BHJT
Base:
Included
MRC:
An indication of whether or not an integral heat source is included.BNHN
Integral Heat Source:
Not included
MRC:
The maximum working pressure at which an item is designed to operate.BPHD
Maximum Working Pressure:
200.0 pounds per square inch
MRC:
Designates the size of the inlet connection included on the item.CPZD
Inlet Connection Size:
0.750 in npt
MRC:
The number of metering tubes provided.CPZF
Metering Tube Quantity:
1
MRC:
The maximum amount of water for which the item is rated,expressed in gallons per minute.CPZG
Maximum Water Capacity In Gallons Per Minute:
5.0
MRC:
The smallest increment of graduation on the dial scale.CPZJ
Dial Scale Smallest Increment:
0.5 gpm
MRC:
An indication of whether or not a dial scale reference pointer is included.CPZK
Dial Scale Reference Pointer:
Included
MRC:
An indication of whether or not an integral pulsation dampener is included.CPZN
Integral Pulsation Dampener:
Not included
MRC:
The inlet connection position for which the item is designed.CPZP
Inlet Connection Position For Which Designed:
Vertical or horizontal
MRC:
Indicates the type of inlet connection device provided.CPZQ
Inlet Connection Device Type:
Stationary
MRC:
The outlet connection position for which the item is designed.CPZR
Outlet Connection Position For Which Designed:
Vertical or horizontal
MRC:
Indicates the type of outlet connection device provided.CPZS
Outlet Connection Device Type:
Stationary
MRC:
An indication of whether or not an alarm signal is included.CPZT
Alarm Signal:
Included
MRC:
Those unusual or unique characteristics or qualities of an item not covered in the other requirements and which are determined to be essential for identification.FEAT
Special Features:
Brass fittings, viton seal material