MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
6.500 inches
MRC:
The distance measured in a straight line from the bottom to the top of an item.ABKW
Overall Height:
3.315 inches
MRC:
An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
Overall Width:
5.125 inches
MRC:
The relationship of the electrical power source to the item.AKWC
Electrical Power Source Relationship:
Operating
MRC:
The number of input alternating current phase(s).ANPM
Input Phase:
Single 2nd operating power rqmt
MRC:
The number of input alternating current phase(s).ANPM
Input Phase:
Single 1st operating power rqmt
MRC:
The number of input alternating current phase(s).ANPM
Input Phase:
Single 3rd operating power rqmt
MRC:
The input value/s/,or range of values,for which the item is rated.APNX
Input Voltage Rating:
200.0 ac volts 2nd operating power rqmt and 240.0 ac volts 2nd operating power rqmt
MRC:
The input value/s/,or range of values,for which the item is rated.APNX
Input Voltage Rating:
210.0 ac volts 1st operating power rqmt and 250.0 ac volts 1st operating power rqmt
MRC:
The input value/s/,or range of values,for which the item is rated.APNX
Input Voltage Rating:
105.0 ac volts 3rd operating power rqmt and 125.0 ac volts 3rd operating power rqmt
MRC:
The output value/s/,or range of values,for which the item is rated.APPA
Output Voltage Rating:
14.2 dc microvolts single power output and 15.74 dc volts single power output
MRC:
The number of complete cyclic changes,per unit of time,for which the input is rated.APTQ
Input Frequency Rating:
50.0 hertz 1st operating power rqmt and 440.0 hertz 1st operating power rqmt
MRC:
The number of complete cyclic changes,per unit of time,for which the input is rated.APTQ
Input Frequency Rating:
50.0 hertz 2nd operating power rqmt and 440.0 hertz 2nd operating power rqmt
MRC:
The number of complete cyclic changes,per unit of time,for which the input is rated.APTQ
Input Frequency Rating:
50.0 hertz 3rd operating power rqmt and 440.0 hertz 3rd operating power rqmt
MRC:
The ambient temperature range at which the item is designed to operate.AYNH
Operating Ambient Tempurature Range:
+0.1/+71.0 degrees celsius
MRC:
Indicates the type of output control provided.BGHY
Output Control Type:
Voltage adjustment single power output
MRC:
The means used to change alternating current voltage to direct current voltage.BHQN
Rectification Method:
Single phase full wave bridge
MRC:
Those features,not otherwise specified,which may be required for proper functioning of the item.CBBL
Features Provided:
Filter
MRC:
The output current rating at which the item is designed to operate.CWGH
Output Current Rating:
1.6 dc amperes single power output and 3.5 dc amperes single power output
MRC:
The maximum alternating current voltage variation which may be present on the direct current output voltage level.CWGZ
Ripple Voltage At Full Load:
1.0 millivolts rms single power output