TXT
묘사:
Transmission Line Test Set
MRC:
The value,or range of values,of root mean square potential for which the item is rated.ACYN
Ac Voltage Rating:
110.0 volts or 220.0 volts
MRC:
The number of complete cyclic changes,per unit of time,for which an item is rated.ACZB
Frequency Rating:
Between 60.0 hertz and 400.0 hertz
MRC:
The relationship of the electrical power source to the item.AKWC
Electrical Power Source Relationship:
Operating
MRC:
An indication of whether or not a facility/ies/ to accommodate a battery/ies/ is included.ALSF
Internal Battery Accommodation:
Included
MRC:
An indication of the feature/s/ of the inclosure.ANPZ
Inclosure Feature:
Single item w/carrying case
MRC:
Indicates the type of test for which the item is designed.AQXY
Test Type For Which Designed:
Tpeak-to-avg ratio; level vs freq; envelope delay; intermodulation distortion; phase & amplitude jitter; noise; phase gain & dropout transients; high & low band singing return loss; echo return loss; sine wave signal return loss
MRC:
The testing functions such as range,sensitivity,output,and the like,for which the item is designed.AQXZ
Operating Test Capability:
20hz to 110khz; m50 to p10dbm
MRC:
The number of alternating current phases.FAAZ
Phase:
Single
MRC:
Characteristics or qualities of an item,not covered in any other requirement,which are considered essential information for one or more functions excluding nsn assignment.SUPP
Supplementary Features:
Rackmount optional and supplied; 2400 baud modem incl; ieee-488 intfc; 5 lbs portable; 10 lbs w/battery