TXT
묘사:
Flow Control Valve
MRC:
The number of end connections included in the item.ADQZ
End Connection Quantity:
2
MRC:
The national stock number or the identification information of the end equipment for which the item is a part.AGAV
End Application:
NSN2-35-001-3904
MRC:
The means used to control the operation of the valve.AQLR
Valve Operation Method:
Automatic
MRC:
Indicates the type of connection/s/.AWLS
Connection Type:
Threaded internal pipe
MRC:
Designates the size of the valve.CCFG
Valve Size:
0.750 inches
MRC:
The maximum pressure at which an item is rated to operate for each type of service with which an item may be used.CQCJ
Maximum Operating Pressure And Media For Which Designed:
2600.0 pounds per square inch hydraulic fluid, petroleum base
MRC:
A designation that is used for the purpose of general identification of the thread.CQJX
Thread Size:
0.750 inches
MRC:
The chemical compound or mechanical mixture properties of which the body is fabricated.CQRG
Body Material:
Steel
MRC:
A rating which expresses the degree of heat or cold as applied to the operation,or limitation of operation,for each type of service with which an item may be used.CRWH
Maximum Operating Tempurature And Media For Which Designed:
115.0 degrees fahrenheit hydraulic fluid, petroleum base
MRC:
A designation distinguishing one group of thread diameter-pitch combinations from another by the number of threads per measurement scale for a specific diameter.THSD
Thread Series Designator:
Nptf