TXT
묘사:
Non Wire Wound Variable Resistor
MRC:
The number of individual elements.AAPN
Section Quantity:
1
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the body.AAQL
Body Style:
Rectangular
MRC:
An indication that the level of probability that an item will operate without failure,at a specified rated capability,at a specified temperature,and for a specified period of time,has been established by testing random samples of production lot.AARG
Reliability Indicator:
Not established
MRC:
A measurement of the longest dimension of a terminal,in distinction from width.ABJT
Terminal Length:
0.200 inches
MRC:
The length of a straight line which passes through the center of a shaft,and terminates at the circumference.ABWV
Shaft Diameter:
0.075 inches
MRC:
A measurement of the longest dimension of the shaft,in distinction from width.ABXF
Shaft Length:
Between 0.025 inches and 0.045 inches
MRC:
A measurement of the longest dimension of the body,in distinction from width.ADAQ
Body Length:
Between 0.230 inches and 0.270 inches
MRC:
A measurement taken at right angles to the length of the body,in distinction from thickness.ADAT
Body Width:
Between 0.165 inches and 0.185 inches
MRC:
A measurement from the bottom to the top of the body,in distinction from depth.ADAU
Body Height:
Between 0.230 inches and 0.270 inches
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the shaft.AEDX
Shaft Style:
Round, slotted
MRC:
Indicates the type of facility or arrangement provided for moving the variable contact(s).AEFD
Actuator Type:
Single shaft
MRC:
The center to center distance between terminals.AEHT
Center To Center Distance Between Terminals:
Between 0.095 inches and 0.105 inches
MRC:
The position of the terminal/s/ for making connection to an item.APXH
Terminal Location:
Rear end
MRC:
The means of attaching the item.AXGY
Mounting Method:
Terminal
MRC:
A measure of the opposition to the flow of direct or alternating current per section.CQCC
Electrical Resistance Per Section:
1.000 kilohms single section
MRC:
The center to center distance between the center terminal and the outside terminal.CQCM
Center To Center Distance Between Center Terminal And Outside Terminal:
Between 0.095 inches and 0.105 inches
MRC:
The maximum amount of electrical energy that can be expended per section,expressed in watts.CRGD
Power Dissipation Rating Per Section In Watts:
0.25 free air single section
MRC:
The limits of permissible variation in the electrical resistance value per section of an item from its rated value,expressed in percent.CRSS
Resistance Tolerance Per Section In Percent:
-5.0/+5.0 single section
MRC:
Indicates the type and number of terminals for providing electrical connection.TTQY
Terminal Type And Quantity:
3 pin