부품 정보
Ends of mtg studs form binding posts
TXT
묘사:
Electrical Frequency Meter
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
2.375 inches
MRC:
The distance measured in a straight line from the bottom to the top of an item.ABKW
Overall Height:
6.250 inches
MRC:
An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
Overall Width:
7.875 inches
MRC:
The distance between mounting facility centers.AEJN
Distance Between Mounting Facility Centers:
5.250 inches
MRC:
Indicates the type of device used to register the condition(s).AMKD
Indicator Type:
Dial w/pointer
MRC:
The installation for which the item is designed.AMQY
Installation Design:
Panel
MRC:
The style designation indicating the configuration that most nearly corresponds to the arrangement of the mounting.ANRL
Mounting Arrangement Style:
Two hole/stud
MRC:
The minimum and maximum frequencies to which the item will respond without exceeding its accuracy rating.ANSY
Frequency Response Range:
+0.000/+20.000 kilohertz
MRC:
The minimum and maximum frequencies to which the item will respond without exceeding its accuracy rating.ANSY
Frequency Response Range:
+0.000 to 20.000 kilohertz
MRC:
The hue or tint of the dial scale marking(s).APMM
Dial Scale Marking Color:
Black single indicator single range
MRC:
An indication of the accuracy of an item,expressed in percent.APPN
Accuracy In Percent:
-2.0/+2.0 at full scale single indicator single range
MRC:
An indication of the accuracy of an item,expressed in percent.APPN
Accuracy In Percent:
-2.0 to 2.0 at full scale single indicator single range
MRC:
A measurement between the mounting flange and the extremity of the meter, indistinction from height.APST
Meter Depth Behind Mounting Flange:
1.750 inches
MRC:
Indicates the type of movement provided.AQEC
Movement Type:
Moving coil, permanent magnet
MRC:
The hue or tint of the background.AQFY
Background Color:
White single indicator single range
MRC:
The hue or tint of the pointer.ASSS
Pointer Color:
Black single indicator single range
MRC:
Indicates the type and number of facilities by which the item is mounted.AXHR
Mounting Facility Type And Quantity:
2 terminal
MRC:
The minimum to maximum value which the item is capable of measuring.BHMW
Measurement Range:
+0.0/+5.5 kilohertz single indicator 1st range+4.5/+10.0 kilohertz single indicator 2nd range+0.0/+11.0 kilohertz single indicator 3rd range+9.0/+20.0 kilohertz single indicator 4th range
MRC:
The minimum to maximum value which the item is capable of measuring.BHMW
Measurement Range:
+0.0 to 11.0 kilohertz single indicator 3rd range
MRC:
The minimum to maximum value which the item is capable of measuring.BHMW
Measurement Range:
+4.5 to 10.0 kilohertz single indicator 2nd range
MRC:
The minimum to maximum value which the item is capable of measuring.BHMW
Measurement Range:
+9.0 to 20.0 kilohertz single indicator 4th range
MRC:
The minimum to maximum value which the item is capable of measuring.BHMW
Measurement Range:
+0.0 to 5.5 kilohertz single indicator 1st range
MRC:
The means provided for selecting a scale.BLSB
Scale Selection Method:
Switch
MRC:
Those features,not otherwise specified,which may be required for proper functioning of the item.CBBL
Features Provided:
Zero adjuster
MRC:
The means employed to suspend the movement of the item.CTQL
Movement Suspension Method:
Jewel pivot base
MRC:
The means provided for electrical connection to a circuit and the number of each type of connection.CTTD
Circuit Attachment Method And Quantity:
2 binding post
MRC:
An indication of the nuclear hardness criticality of the item.NHCF
Nuclear Hardness Critical Feature:
Nonhardened
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the item.STYL
Style Designator:
Rectangular flush mtg