100 mhz ruggedized oscilloscope
MRC:
An overall measurement between specified points of an item,in distinction from height.ABFY
Overall Depth:
17.000 inches
MRC:
The distance measured in a straight line from the bottom to the top of an item.ABKW
Overall Height:
8.300 inches
MRC:
An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
Overall Width:
10.800 inches
MRC:
Indicates the type of current whether alternating,direct,or both.ACDC
Current Type:
Ac
MRC:
The number of complete cyclic changes,per unit of time,for which an item is rated.ACZB
Frequency Rating:
Between 48.0 hertz and 440.0 hertz
MRC:
The value(s) of potential for which the item is rated.AMSE
Voltage Rating:
Between 100.0 volts and 132.0 volts
MRC:
The number of beams provided on the item.ATES
Beam Quantity:
2
MRC:
The acceptable limits of deviation from the designed standard output value of the item,expressed in percent.BDJD
Accuracy Range In Percent:
-4.0/+4.0
MRC:
An indication of whether or not sweep circuits are included.BGQL
Sweep Circuits:
Included
MRC:
An indication of whether or not a generator driven feature is included.BGQM
Generator Driven Feature:
Not included
MRC:
Indicates the type of sweep circuits provided.BGQN
Sweep Circuit Type:
Horizontal and vertical
MRC:
The range of complete cyclic changes,per unit of time,for which the sweep is rated.BGQP
Sweep Frequency Range:
+0.0/+100.0 megahertz
MRC:
The length of time consumed by a single trigger sweep.BGQQ
Single Trigger Sweep Duration:
Between 50.0 nanoseconds and 5.0 seconds
MRC:
The minimum and maximum frequencies to which the x-axis will respond.BHDQ
X-axis Frequency Response Rating:
0.0 megahertz and 2.0 megahertz
MRC:
The minimum and maximum frequencies to which the y-axis will respond.BHDR
Y-axis Frequency Response Rating:
0.0 megahertz and 100.0 megahertz
MRC:
An indication of the shape of the amplitude calibrating voltage waveform.BHDZ
Amplitude Calibrating Voltage Waveform:
Square wave
MRC:
An indication of whether or not a trace storage tube is included.BHFH
Trace Storage Tube:
Included
MRC:
The alpha-numeric designation that identifies the classification of the item according to the category of functions performed.FCLS
Functional Classification:
Aa-9.3
MRC:
Those unusual or unique characteristics or qualities of an item not covered in the other requirements and which are determined to be essential for identification.FEAT
Special Features:
Bdc to 100 mhz bandwidth; integrated counter/timer; 2mv sensitivity; advanced trigger system; 5 ns/div sweep rate; delayed sweep measurements; 10x probe; 9 digit, 7 segment vacuum-fluoresent panel
MRC:
Describes the capabilities,intended use,and/or purpose for which the item is provided.FTLD
Functional Description: