MRC:
The specification,standard,drawing,or similar instrument that specifies environmental and performance requirements or test conditions under which an item is tested and establishes acceptable limits within which the item must conform identified by an alphabetic and/or numeric reference number. includes the commercial and government entity (cage) code of the entity controlling the instrument.TEST
Test Data Document:
82577-h8000526 drawing (this is the basic governing drawing, such as a contractor drawing, original equipment manufacturer drawing, etc.; excludes any specification, standard or other document that may be referenced in a basic governing drawing)
MRC:
A recording of the physical,functional,and performance characteristics for an item of supply.TEXT
General Description:
20kv input to output isolation voltage; -55 to +85 degrees c op temp range; input diode 40 milliamps forward current, 3v reverse voltage; output detector -0.5 to 7v supply and output voltage range, 25 milliamps output current, 40 milliwatts output collector power dissipation; case dimensions 0.75 in lg, 0.5 in wd, 0.5 in ht; 5 uninsulated wire leads.