TXT
묘사:
Safety Relief Valve
MRC:
The part that controls the flow through the item.ADQU
Flow Control Device:
Disk
MRC:
The means of closing the item when inlet pressure decreases.ADSU
Disk Loading Method:
Spring
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the connection.AHNC
Connection Style:
Streamlined with one brazing ring (tube) err-100
MRC:
The means used to control the operation of the valve.AQLR
Valve Operation Method:
Automatic
MRC:
Indicates the type of connection/s/.AWLS
Connection Type:
Unthreaded internal tube 2nd end
MRC:
Indicates the type of connection/s/.AWLS
Connection Type:
Unthreaded internal tube 1st end
MRC:
The minimum to maximum pressures at which the item may be set to open.CQCY
Adjustable Pressure Range:
+18.0/+29.0 pounds per square inch
MRC:
The nominal length of a straight line which passes through the center of the accommodated tube,and terminates at the outside circumference.CWFD
Outside Diameter Tube Accommodated:
0.375 inches 2nd end
MRC:
The nominal length of a straight line which passes through the center of the accommodated tube,and terminates at the outside circumference.CWFD
Outside Diameter Tube Accommodated:
0.500 inches 1st end
MRC:
The chemical compound or mechanical mixture properties of which the item is fabricated.MATT
Material:
Copper alloy body
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the item.STYL
Style Designator:
Err-090