MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the body.AAQL
Body Style:
Hole mounted
MRC:
The specific commercial rating which classes the item as to what degree the item will withstand environmental elements and/or hazardous locations.ABFE
Hazardous Locations/environmental Protection:
Oiltight
MRC:
The measurement of the distance that the actuator protrudes from the body.AFGK
Actuator Length:
1.250 inches
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the actuator.AFUQ
Actuator Style:
Roller arm
Actuator Height:
0.750 inches
Actuator Roller Diameter:
0.750 inches
Actuator Roller Width:
0.250 inches
MRC:
A measurement of the longest dimension of the housing,in distinction from width.AFWD
Housing Length:
4.953 inches
MRC:
A measurement taken at right angles to the length of a housing,in distinction from thickness.AFWE
Housing Width:
2.312 inches
Center To Center Distance Between Housing Mounting Facilities Parallel To Width:
2.062 inches
MRC:
The maximum voltage rating at which the item is designed to operate in an alternating current and/or direct current circuit,expressed in volts.AFXE
Maximum Voltage Rating In Volts:
220.0 ac and 220.0 dc
MRC:
Indicates the type of inclosure provided to coat,cover,protect,or encase the item.AKNA
Inclosure Type:
Fully enclosed
MRC:
The amount of force required to actuate the switch.CSJN
Switch Actuating Force:
150.0 inch-ounces
MRC:
The movement of the switch actuator.CXQQ
Actuator Movement:
11.0 differential degrees and 17.0 pretravel degrees
MRC:
The amount of current the contacts are rated to make or break at maximum rated voltage,with a specified load.CXQR
Contact Load Current Rating At Maximum Rated Voltage:
1.000 amperes resistive dc and 3.000 amperes resistive ac