TXT
				
				
					묘사:
				
				
					Electrical Power Cable				
			 
			
										
					
						MRC:
						The style designation indicating the configuration that most nearly corresponds to the cross-sectional shape of the item.AAGR
					 
					
						Cross Sectional Shape:
					
					
						Round					
				 
							
					
						MRC:
						A value which expresses the degree of heat or cold as applied to the operation,or limitation of operation,of an item.ABJH
					 
					
						Tempurature Rating:
					
					
						150.0 degrees celsius					
				 
							
					
						MRC:
						The national stock number or the identification information of the end equipment for which the item is a part.AGAV
					 
					
						End Application:
					
					
						Mrap rg-33					
				 
							
					
						MRC:
						The number of electrical conductors included on the item.AMQN
					 
					
						Conductor Quantity:
					
					
						5					
				 
							
					
						MRC:
						The number of strands per conductor.BLNZ
					 
					
						Strand Quantity Per Conductor:
					
					
						37 all conductors					
				 
							
					
						MRC:
						The fabricated form of the conductor.CXCW
					 
					
						Conductor Form:
					
					
						Stranded all conductors					
				 
							
					
						MRC:
						The designation used to describe the round stranded or round solid conductor size.CXDC
					 
					
						Round Conductor Size:
					
					
						12 awg all conductors					
				 
							
					
						MRC:
						The american wire gage size of the individual strands of wire used in each stranded conductor.CXDG
					 
					
						Strand Awg Size Per Conductor:
					
					
						28 all conductors					
				 
							
					
						MRC:
						The arrangement and number of arrangements of the conductors.CXDQ
					 
					
						Conductor Arrangement And Quantity:
					
					
						5 singles					
				 
							
					
						MRC:
						The maximum sustained voltage that can be safely applied to the item without risking failure or damage.CXFK
					 
					
						Voltage Rating:
					
					
						600.0  root mean square (rms) operating voltage all conductors					
				 
							
					
						MRC:
						The chemical compound or mechanical mixture properties of which the item is fabricated.MATT
					 
					
						Material:
					
					
						Copper 1st position shield braid,  metallic cable					
				 
							
					
						MRC:
						The chemical compound or mechanical mixture properties of which the item is fabricated.MATT
					 
					
						Material:
					
					
						Copper alloy 101  or copper alloy 102 core conductor all conductors					
				 
							
					
						MRC:
						The chemical compound or mechanical mixture properties of which the item is fabricated.MATT
					 
					
						Material:
					
					
						Plastic cross-linked polyalkene 1st position primary insulation all conductors					
				 
							
					
						MRC:
						The chemical compound or mechanical mixture properties of which the item is fabricated.MATT
					 
					
						Material:
					
					
						Plastic cross-linked polyvinylidene fluoride 2nd position jacket all conductors					
				 
							
					
						MRC:
						The chemical compound or mechanical mixture properties of which the item is fabricated.MATT
					 
					
						Material:
					
					
						Plastic cross-linked polyvinylidene fluoride 2nd position jacket cable					
				 
							
					
						MRC:
						The specification,standard,or manufacturers reference,and the classification designation,such as class,condition,temper,and the like,that identifies the material.MDCL
					 
					
						Material Specification:
					
					
						Astm b33 assn standard single material response core conductor all conductors					
				 
							
					
						MRC:
						The metallic,nonmetallic,and/or chemical properties with which the item is plated,dipped,and/or coated.the treatment is designed to protect the surface(s) and cannot be wiped off.SFTT
					 
					
						Surface Treatment:
					
					
						Tin 1st position shield braid,  metallic cable					
				 
							
					
						MRC:
						The metallic,nonmetallic,and/or chemical properties with which the item is plated,dipped,and/or coated.the treatment is designed to protect the surface(s) and cannot be wiped off.SFTT
					 
					
						Surface Treatment:
					
					
						Tin core conductor all conductors					
				 
							
					
						MRC:
						The specification,standard,or manufacturers reference,and the classification designation,such as type,class,grade,and the like,that identifies the surface treatment material.STDC
					 
					
						Surface Treatment Specification:
					
					
						Astm b33 assn standard single treatment response core conductor all conductors					
				 
							
					
						MRC:
						The specification,standard,or manufacturers reference,and the classification designation,such as type,class,grade,and the like,that identifies the surface treatment material.STDC
					 
					
						Surface Treatment Specification:
					
					
						Astm b33 assn standard single treatment response 1st position shield braid,  metallic cable