Drawing: outline and certification data, 3 x 3-1/2 - 9nc - 1, demineralized water cooling pump, 9c-3500-40a
MRC:
Indicates the type of mount utilized to support the item.AAXX
Mounting Type:
Base
MRC:
The type of service with which the item is designed to be used.ACKL
Media For Which Designed:
Water, distilled
MRC:
The national stock number or the identification information of the end equipment for which the item is a part.AGAV
End Application:
Centrifugal pump
MRC:
The maximum rated capacity delivered by the item.AHYV
Maximum Discharge Flow Rate:
330.0 gallons per minute
MRC:
The sum of the total discharge head and the total suction lift.AHYX
Total Head:
278.000 feet
MRC:
The speed of the item required to produce its rated capacity.AHYZ
Operating Speed At Rated Capacity:
3575.0 revolutions per minute
MRC:
The position in which the pumping element/s/ is designed to operate.AHZA
Pumping Element Operating Position:
Horizontal
MRC:
Those unusual or unique characteristics or qualities of an item not covered in the other requirements and which are determined to be essential for identification.FEAT
Special Features:
Suction pressure: 40 psig max; submergence: flooded; suction temperature: p90 to p 115 degrees f; actual shut off head: 311 ft; rated input: 33 bhp; hydrostatic test pressure: 250 psig; rated output: 40 bhp; windings: squirrel cage: enclosure: tefc; torque class: design b; navy service: a; bearings: ball; frame: 326tnc; insulation: f w/sealed insulation system