부품 번호 MS3400D40-56S

Electrical Receptacle Connector

가격 및 가용성

이 NSN의 현재 가격 및 가용성에 대해 이 양식을 제출하십시오.
부품 번호:
양:
이메일 주소:
전화:
참조:
회사:
이름:

우리는 귀하의 정보를 누구에게도 공유하거나 판매하지 않습니다.
사생활 | 용어

All major credit cards accepted as well as gov. p-cards

이 제품의 과거 가격은 350.32 and 472.932 USD. 수량, 가용성, 상태, 리드 타임 및 품목 중단 가능성에 따라 최신 견적을 제공할 때까지 가격을 보장할 수 없습니다.

부품 번호
비무장화
수명
UOM
NIIN
부품 번호:
ms3400d40-56s
비무장화:
No
수명:
N/A
측정 단위:
1 EA
NIIN:
006220488
NSN
국가 주식 번호:
5935-00-622-0488 5935006220488
TXT
묘사:
Electrical Receptacle Connector
INC
INC
아이템 이름 코드:
15093
MRC:
A numeric-alpha designator indicating the pitch diameter tolerance and an external or internal thread.AAJD
Thread Class:
2a and 2a
MRC:
The direction of the thread when viewed axially. a right-hand thread winds in a clockwise direction while a left-hand thread winds in a counterclockwise direction.AAJF
Thread Direction:
Right-hand and right-hand
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the body.AAQL
Body Style:
Straight shape, external coupling
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
2.125 inches
MRC:
The distance measured in a straight line from the bottom to the top of an item.ABKW
Overall Height:
Between 2.531 inches and 2.719 inches
MRC:
An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
Overall Width:
Between 2.531 inches and 2.719 inches
MRC:
The environmental elements or conditions that an item is designed or protected to resist or withstand satisfactorily.ADZC
Environmental Protection:
Moisture resistant and salt water resistant and vibration resistant
MRC:
The length of a straight line which passes through the center of an unthreaded mounting hole,and terminates at the circumference.AEBV
Unthreaded Mounting Hole Diameter:
Between 0.168 inches and 0.183 inches
MRC:
The distance between the center of one mounting facility and the center of the adjacent mounting facility parallel to the height.AEBW
Center To Center Distance Between Mounting Facilities Parallel To Height:
2.188 inches
MRC:
The distance between centerlines of mounting facilities parallel to the width of the item.AEHA
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width:
2.188 inches
MRC:
None.AFQK
Distance From Mounting Shoulder To Front Face:
Between 0.875 inches and 0.906 inches
MRC:
Indicates the type of threaded device included on the item.AFQR
Threaded Device Type:
Back shell and coupling facility
MRC:
The number of mating ends provided with the item which are designed to accommodate another connector.AFQW
Mating End Quantity:
1
MRC:
The style designation indicating the configuration that most nearly corresponds to the arrangement of the contact position/s/.AFQX
Contact Position Arrangement Style:
40-56 single mating end
MRC:
An indication of whether or not the contact(s) is removable.AFQZ
Contact Removability:
Removable single mating end single contact grouping
MRC:
The maximum current which the contact may continuously carry without degradation or destruction,expressed in amperes.AFRC
Contact Maximum Current Rating In Amps:
22.0 single mating end single contact grouping
MRC:
The maximum alternating current potential that may be applied continuously to the contact without damage,expressed in volts.AFRD
Contact Maximum Ac Voltage Rating In Volts:
500.0 single mating end single contact grouping
MRC:
The maximum direct current potential that may be applied continuously to the contact without damage,expressed in volts.AFRE
Contact Maximum Dc Voltage Rating In Volts:
700.0 single mating end single contact grouping
MRC:
The means used to prevent mismating or cross plugging of contacts.AFRN
Polarization Method:
Keyway or multiple keyway
MRC:
The amount of clockwise displacement of the indexing radius of the insert from normal position,expressed in degrees.AFRP
Insert Position In Deg:
0.0
MRC:
Indicates the type of shell included on the item.AFRT
Shell Type:
Solid
MRC:
The means used to secure a connector to its mating counterpart.AFRV
Connector Locking Method:
Externally threaded shell
MRC:
A nominal measurement of the extent of threads,including incomplete threads,along a line parallel to the longitudinal axis.AKMG
Thread Length:
0.467 inches and 0.625 inches
MRC:
The number of threads on the item per linear inch measured on a line parallel to the thread axis.CMLP
Thready Qty Per Inch (tpi):
16 and 16
MRC:
A designation that is used for the purpose of general identification of the thread.CQJX
Thread Size:
2.500 inches and 2.500 inches
MRC:
Indicates the location of the terminal/s/ on the item.CQTM
Terminal Location:
Back single mating end single contact grouping
MRC:
The chemical compound or mechanical mixture properties of which the insert is fabricated.CQZG
Insert Material:
Plastic silicone single mating end
MRC:
Indicates the type of terminal for providing electrical connection to the item.CSCF
Terminal Type:
Crimp single mating end single contact grouping
MRC:
The chemical compound or mechanical mixture properties of which the shell is fabricated.CSPT
Shell Material:
Aluminum alloy
MRC:
The metallic,nonmetallic,and/or chemical properties with which the item is plated,dipped,and/or coated.the treatment is designed to protect the shell surface/s/ and cannot be wiped off.CSWM
Shell Surface Treatment:
Cadmium
MRC:
The specification,standard,or manufacturers reference,and the classification designation,such as type,class,grade,and the like that identifies the shell surface treatment material.CTBC
Shell Surface Treatment Specification:
Qq-p-416, type 2, cl 3 federal specification single treatment response
MRC:
The number of contacts included with the item which provides electrical connection.CXCG
Included Contact Quantity:
85 single mating end single contact grouping
MRC:
Indicates the type of contact(s) included with the item.CXCL
Included Contact Type:
Round socket single mating end single contact grouping
MRC:
The specification,standard,drawing,or similar instrument that specifies environmental and performance requirements or test conditions under which an item is tested and establishes acceptable limits within which the item must conform identified by an alphabetic and/or numeric reference number. includes the commercial and government entity (cage) code of the entity controlling the instrument.TEST
Test Data Document:
81349-mil-c-5015 specification (includes engineering type bulletins, brochures, etc., that reflect specification type data in specification format; excludes commercial catalogs, industry directories, and similar trade publications, reflecting general type data on certain environmental and performance requirements and test conditions that are shown as "typical", "average", "", etc.).
MRC:
A designation distinguishing one group of thread diameter-pitch combinations from another by the number of threads per measurement scale for a specific diameter.THSD
Thread Series Designator:
Un and un
MRC:
The document designator of the specification or standard which established the item of supply.ZZZK
Specification Data:
81349-mil-c-5015 government specification

{lang[cimilar]} Electrical Receptacle Connectors

« Electrical Connectors {lang[catalog]}
지금 비교»
맑다 | 숨기다