TXT
묘사:
Liquid Refrigerant Receiver
MRC:
The direction of the thread when viewed axially. a right-hand thread winds in a clockwise direction while a left-hand thread winds in a counterclockwise direction.AAJF
Thread Direction:
Right-hand
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
Between 19.750 inches and 20.250 inches
MRC:
Designates the thread diameter and number of threads per specific measurement scale.ABUJ
Thread Size:
1/2 in.-14
MRC:
The type of service with which the item is designed to be used.ACKL
Media For Which Designed:
Refrigerant 12
MRC:
The installed position for which the item is designed.ADSM
Mounting Position:
Horizontal
MRC:
A designation distinguishing one group of screw thread diameter-pitch combinations from another by the number of threads per measurement scale for a specific diameter.AJYP
Screw Thread Series Designator:
Nptf
MRC:
An indication of whether or not a shutoff valve/s/ is provided.ASPS
Shutoff Valve:
Not provided
MRC:
The length of a straight line which passes through the center of the shell,and terminates at the outside circumference.AWKS
Shell Outside Diameter:
6.000 inches
MRC:
The refrigerant temperature at the minimum capacity,expressed in degrees fahrenheit.AWMD
Err Default:
Err default
MRC:
The refrigerant temperature at the minimum capacity,expressed in degrees fahrenheit.AWMD
Refrigerant Tempurature At Minimum Capacity In Deg Fahrenheit:
135.000
MRC:
An indication of whether or not an equalizing connection feature is included.AWMM
Equalizing Connection Feature:
Included
MRC:
An indication of whether or not a drain connection is included.AWMN
Drain Connection:
Not included
MRC:
An indication of whether or not a safety plug is included.AWMP
Safety Plug:
Not included
MRC:
An indication of whether or not a liquid level indicator is included.AWMQ
Liquid Level Indicator:
Not included
MRC:
Indicates the type of end connection and its location on the item.AWPR
End Connection Type And Location:
Threaded internal pipe first end err-100
MRC:
Indicates the type of end connection and its location on the item.AWPR
End Connection Type And Location:
Threaded internal pipe second end err-100
MRC:
Indicates the type of end connection and its location on the item.AWPR
End Connection Type And Location:
Threaded internal pipe first end
MRC:
Indicates the type of end connection and its location on the item.AWPR
End Connection Type And Location:
Threaded internal pipe second end
MRC:
The special design of the connection.AWPS
Connection Specificationial Design:
Union
MRC:
The amount of refrigerant the item will hold.AWXK
Refrigerant Capacity:
18.000 pounds
MRC:
The minimum capacity of the item.AWXL
Err Default:
Err default
MRC:
The minimum capacity of the item.AWXL
Minimum Capacity:
450.0 cubic inches
MRC:
The element,compound,or mixture of which an item is fabricated,excluding any surface treatment.MATL
Material:
Steel
MRC:
The chemical compound or mechanical mixture properties of which the item is fabricated.MATT
Material:
Steel
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the item.STYL
Style Designator:
Threaded