부품 번호:
						ms-28-f-sma-1-ttl-de9p					
 
					
					
					
					
				 
			 
						
			
				
					TXT
				
				
					묘사:
				
				
					Radio Frequency Transmiss Switch				
			 
			
										
					
						MRC:
						The style designation indicating the configuration that most nearly corresponds to the appearance of the body.AAQL
					 
					
						Body Style:
					
					
						Rectangular					
				 
							
					
						MRC:
						The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
					 
					
						Overall Length:
					
					
						2.400 inches 					
				 
							
					
						MRC:
						The distance measured in a straight line from the bottom to the top of an item.ABKW
					 
					
						Overall Height:
					
					
						1.198 inches 					
				 
							
					
						MRC:
						An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
					 
					
						Overall Width:
					
					
						0.500 inches 					
				 
							
					
						MRC:
						The number of complete cyclic changes,per unit of time,for which an item is rated.ACZB
					 
					
						Frequency Rating:
					
					
						20.0 megahertz  single frequency operating and 300.0 megahertz  single frequency operating					
				 
							
					
						MRC:
						The length of a straight line which passes through the center of an unthreaded mounting hole,and terminates at the circumference.AEBV
					 
					
						Unthreaded Mounting Hole Diameter:
					
					
						0.120 inches  and 0.093 inches 					
				 
							
					
						MRC:
						Indicates the type of switch included in the item.AEEA
					 
					
						Switch Type:
					
					
						Nontransfer					
				 
							
					
						MRC:
						The distance between mounting facility centers.AEJN
					 
					
						Distance Between Mounting Facility Centers:
					
					
						0.090 inches  single mounting facility pattern					
				 
							
					
						MRC:
						The longest distance between mounting centers parallel to the horizontal plane.AFDS
					 
					
						Longest Horizontal Distance Between Mounting Centers:
					
					
						0.440 inches  single mounting facility pattern					
				 
							
					
						MRC:
						The minimum and maximum limits of temperature at which the item is rated for operation.AFGA
					 
					
						Operating Tempurature Range:
					
					
						-55.0/+85.0 degrees celsius					
				 
							
					
						MRC:
						The national stock number or the identification information of the end equipment for which the item is a part.AGAV
					 
					
						End Application:
					
					
						Solar elec/opti ntwk					
				 
							
					
						MRC:
						The ratio of the maximum to the minimum amplitude of pressure /voltage/ measured along the path of the waves.AHTW
					 
					
						Voltage Standing Wave Ratio:
					
					
						1.20 single					
				 
							
					
						MRC:
						The difference in the amount of energy available before and after the insertion of an apparatus in a transmission system,expressed in decibels.AHTX
					 
					
						Insertion Loss In Decibels:
					
					
						0.20 single					
				 
							
					
						MRC:
						A letter or group of letters used to designate the particular coaxial connector series.AHUC
					 
					
						Coaxial Connector Series Designation:
					
					
						Sma					
				 
							
					
						MRC:
						The design of the connector end.AHUD
					 
					
						Connector End Design:
					
					
						Female					
				 
							
					
						MRC:
						The minimum amount of isolation the item offers against interference from adjacent channel operation,expressed in decibels.AKNV
					 
					
						Minimum Crosstalk Rating In Decibels:
					
					
						80.0 single					
				 
							
					
						MRC:
						The means provided for switching the actuator from one position to another.AKPC
					 
					
						Actuator Operating Method:
					
					
						Relay					
				 
							
					
						MRC:
						The actuator current type and amount of electron flow at which the item is designed to operate,expressed in amperes.AKPE
					 
					
						Actuator Current Type And Rating In Amps:
					
					
						0.147 dc 					
				 
							
					
						MRC:
						The value/s/,or range of values,of potential for which the item is rated,expressed in volts.AKPJ
					 
					
						Actuator Voltage In Volts:
					
					
						28.0 					
				 
							
					
						MRC:
						An indication of whether the lobe of the rotating cam is designed to actuate /make/ a switch before or after the preceding switch deactuates /breaks/.AKPN
					 
					
						Switch Operation Sequence:
					
					
						Makes before breaks					
				 
							
					
						MRC:
						The time required for switching between any two adjacent positions.AKPP
					 
					
						Switching Time:
					
					
						20.0 milliseconds					
				 
							
					
						MRC:
						The operation of the switch mechanism when the switch return actuator power is removed.AKPQ
					 
					
						Switch Return Mechanism Type:
					
					
						Fail-safe					
				 
							
					
						MRC:
						The number of poles included in the item.AKPX
					 
					
						Pole Quantity:
					
					
						1					
				 
							
					
						MRC:
						The number of positions to which the item may be actuated to energize electrical circuits.AKPY
					 
					
						Throw Quantity:
					
					
						2					
				 
							
					
						MRC:
						The number of coupling positions provided.AKRC
					 
					
						Coupling Position Quantity:
					
					
						2					
				 
							
					
						MRC:
						Indicates the type and number of facilities by which the item is mounted.AXHR
					 
					
						Mounting Facility Type And Quantity:
					
					
						4 unthreaded hole					
				 
							
					
						MRC:
						The general configuration and relative position of the facilities provided for mounting the item.CQYJ
					 
					
						Mounting Facility Pattern:
					
					
						Four position rectangular single mounting facility pattern					
				 
							
					
						MRC:
						The chemical compound or mechanical mixture properties of which the item is fabricated.MATT
					 
					
						Material:
					
					
						Aluminum alloy body					
				 
							
					
						MRC:
						Indicates the type and number of terminals for providing electrical connection.TTQY
					 
					
						Terminal Type And Quantity:
					
					
						3 receptacle,  coaxial