부품 정보
						Hardness critical item
					 
				 
						
			
			
										
					
						MRC:
						The different speeds at which the item may be operated.ABBB
					 
					
						Speed Adjustments:
					
					
						0 to full speed					
				 
							
					
						MRC:
						A measurement of the longest dimension of any object,in distinction from width.ABRY
					 
					
						Length:
					
					
						10.000 inches 					
				 
							
					
						MRC:
						The direction in which the fluid is passed through the item.ADNK
					 
					
						Flow Direction:
					
					
						Inward					
				 
							
					
						MRC:
						The temperature of the medium surrounding an item at which it can be operated continuously at full rated power.AEHY
					 
					
						Ambient Tempurature At Full Rated Power:
					
					
						-50.0 degrees fahrenheit and 160.0 degrees fahrenheit					
				 
							
					
						MRC:
						Indicates the type of electrical connection included on the item.AGBD
					 
					
						Electrical Connection Type:
					
					
						Connector receptacle					
				 
							
					
						MRC:
						The static pressure measured at the air flow rate specified.AJLY
					 
					
						Static Pressure At Specificationified Air Flow Rate:
					
					
						2.1 inches of water					
				 
							
					
						MRC:
						Indicates the type of drive for turning,rotating,or positioning the mechanism.AKCV
					 
					
						Drive Type:
					
					
						Direct					
				 
							
					
						MRC:
						Indicates the type of prime mover included with the unit.AKDJ
					 
					
						Prime Mover Type:
					
					
						Electric motor					
				 
							
					
						MRC:
						Indicates the type of inclosure provided to coat,cover,protect,or encase the item.AKNA
					 
					
						Inclosure Type:
					
					
						Fully enclosed					
				 
							
					
						MRC:
						Indicates the type and number of facilities by which the item is mounted.AXHR
					 
					
						Mounting Facility Type And Quantity:
					
					
						1 flange					
				 
							
					
						MRC:
						The direction of rotation for which the item is designed.AYSY
					 
					
						Rotation Direction For Which Designed:
					
					
						Counterclockwise					
				 
							
					
						MRC:
						The rated capacity of air flow moved through the item.CQKX
					 
					
						Air Flow Rate:
					
					
						820.0 cubic feet per minute 					
				 
							
					
						MRC:
						The master requirement codes of those requirements which are technically critical by reason of tolerance,fit,performance,or other characteristics which affect identification of the item.CRTL
					 
					
						Criticality Code Justification:
					
					
						Feat					
				 
							
					
						MRC:
						The total electrical voltage,expressed in volts,and the type of current whether alternating or direct.CSBH
					 
					
						Voltage In Volts And Current Type:
					
					
						208.0 ac					
				 
							
					
						MRC:
						The rated power of the prime mover.CSYL
					 
					
						Prime Mover Power Rating:
					
					
						830.000 watts					
				 
							
					
					
						Housing Inside Diameter:
					
					
						10.000 inches 					
				 
							
					
						MRC:
						Indicates the type of bearing/s/ provided on the prime mover drive shaft.CWLY
					 
					
						Prime Mover Drive Shaft Bearing Type:
					
					
						Ball					
				 
							
					
						MRC:
						The number of alternating current phases.FAAZ
					 
					
						Phase:
					
					
						Three					
				 
							
					
						MRC:
						The cycles per second /hertz/ of the alternating current.FREQ
					 
					
						Frequency In Hertz:
					
					
						60.0					
				 
							
					
						MRC:
						The chemical compound or mechanical mixture properties of which the item is fabricated.MATT
					 
					
						Material:
					
					
						Aluminum alloy 356.0 					
				 
							
					
						MRC:
						The specification,standard,or manufacturers reference,and the classification designation,such as class,condition,temper,and the like,that identifies the material.MDCL
					 
					
						Material Specification:
					
					
						Ams4217 assn standard single material response 					
				 
							
					
						MRC:
						An indication of the nuclear hardness criticality of the item.NHCF
					 
					
						Nuclear Hardness Critical Feature:
					
					
						Hardened					
				 
							
					
						MRC:
						The metallic,nonmetallic,and/or chemical properties with which the item is plated,dipped,and/or coated.the treatment is designed to protect the surface(s) and cannot be wiped off.SFTT
					 
					
						Surface Treatment:
					
					
						Plastic epoxy 					
				 
							
					
						MRC:
						The specification,standard,or manufacturers reference,and the classification designation,such as type,class,grade,and the like,that identifies the surface treatment material.STDC
					 
					
						Surface Treatment Specification:
					
					
						Mil-p-23377d military specification single treatment response 					
				 
							
					
						MRC:
						The style designation indicating the configuration that most nearly corresponds to the appearance of the item.STYL
					 
					
						Style Designator:
					
					
						Fixed