부품 정보
850.000 btu perhr min discharge
TXT
묘사:
Pressure And Temper Relief Valve
MRC:
The basic material of which the body is fabricated.AAFZ
Body Material:
Bronze, astm b61 and bronze, astm b62
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the body.AAQL
Body Style:
Angle give "adqm" and "adqn" only if flanged one or two ends
MRC:
The element, compound,or mixture of which the stem is fabricated,excluding any surface treatment.ABEP
Stem Material:
Bronze, astm b61 and bronze, astm b62
MRC:
Items furnished as accessories which are not specified elsewhere.ABFF
Furnished Items:
Emergency opening device and reducing bushing, brass, 2 in. By 1 in.
MRC:
A value which expresses the degree of heat or cold as applied to the operation,or limitation of operation,of an item.ABJH
Tempurature Rating:
210.0 degrees fahrenheit
MRC:
The type of service with which the item is designed to be used.ACKL
Media For Which Designed:
Water, fresh
MRC:
A narrative description of the type of end connection.ACKM
First End Connection Type:
Threaded internal pipe
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the end.ACKN
First End Style Designator:
Plain
MRC:
The industrial designation or term used to define the nominal diameter of the pipe the end will accommodate.ACLG
First End Pipe Size Accommodated:
1.000 inches
MRC:
The direction of the thread when viewed axially. a right-hand thread winds in a clockwise direction while a left-hand thread winds in a counterclockwise direction.ACLL
First End Thread Direction:
Right-hand
MRC:
Indicates whether or not the second end is identical to the first end.ACLR
Second End Relationship With First End:
Not identical
MRC:
A narrative description of the type of end connection.ACLS
Second End Connection Type:
Threaded external pipe
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the end.ACLT
Second End Style Designator:
Plain
MRC:
The industrial designation or term used to define the nominal diameter of the pipe the end will accommodate.ACMN
Second End Pipe Size Accommodated:
1.000 inches
MRC:
The direction of the thread when viewed axially. a right-hand thread winds in a clockwise direction while a left-hand thread winds in a counterclockwise direction.ACMS
Second End Thread Direction:
Right-hand
MRC:
The element,compound,or mixture of which the seating surfaces are fabricated.ACSH
Seat Material:
Bronze, astm b61 and bronze, astm b62
MRC:
The part that controls the flow through the item.ADQU
Flow Control Device:
Poppet
MRC:
The element,compound,or mixture of which the flow control device is fabricated.ADQV
Flow Control Device Material:
Silicone
MRC:
The number of end connections included in the item.ADQZ
End Connection Quantity:
2
MRC:
The predetermined pressure at which the item is calibrated to open.ADSV
Opening Pressure Setting:
75.0 pounds per square inch
MRC:
An indication of whether or not the temperature is adjustable.AEVX
Tempurature Adjustability:
Not adjustable
MRC:
Indicates the type of temperature control device that actuates the item.AFKX
Tempurature Control Device Type:
Thermostatic
MRC:
The number,letter,or symbol that indicates the type,style,grade,class,and the like,of an item in a nonidentifying specification or standard.ZZZT
Specification Or Standard:
1 type and 2 class and x size