TXT
묘사:
Direct Current Motor
MRC:
The distance measured in a straight line from the bottom to the top of an item.AAJT
Overall Height:
26.500 inches
MRC:
A measurement of the longest dimension of an item,in distinction from width.AAJU
Overall Length:
44.063 inches
MRC:
An overall measurement taken at right angles to the length of an item,in distinction from thickness.AAJV
Overall Width:
32.188 inches
MRC:
A measurement taken at right angles to the length of a keyway,in distinction from thickness.ABRR
Keyway Width:
0.5000 inches identical ends
MRC:
A measurement from the top surface to the bottom of the keyway groove.ABRV
Keyway Depth:
0.3750 inches identical ends
MRC:
The length of a straight line which passes through the center of a shaft,and terminates at the circumference.ABWV
Shaft Diameter:
2.1250 inches second end
MRC:
The length of a straight line which passes through the center of a shaft,and terminates at the circumference.ABWV
Shaft Diameter:
2.2500 inches first end
MRC:
The working period under which the item was designed to operate.AKPS
Duty Cycle:
Continuous
MRC:
An indication of the feature/s/ of the inclosure.ANPZ
Inclosure Feature:
Watertight
MRC:
Indicates the specific arrangement in which wire is wound on a form or is formed by winding.AXCP
Winding Type:
Compound wound
MRC:
The means of attaching the item.AXGY
Mounting Method:
Fixed base
MRC:
Indicates the type and number of facilities by which the item is mounted.AXHR
Mounting Facility Type And Quantity:
4 unthreaded hole
MRC:
The means of cooling used to maintain the required operating temperature of the item.BFMF
Cooling Method:
Self-ventilated
MRC:
The means by which the current is rated.BKPB
Current Rating Method:
Load
MRC:
The government or industrial specification or standard that defines the inclosure feature.BKPQ
Inclosure Specificationification:
Mil-std-108
MRC:
Those features,not otherwise specified,which may be required for proper functioning of the item.CBBL
Features Provided:
Vertical mounting position
MRC:
The amount of electrical energy that can be dissipated.CNXS
Power Rating:
30.0000 horsepower output
MRC:
A measurement of the longest dimension of the shaft projection of an item,in distinction from width.CWCS
Length Of Shaft From Housing:
4.375 inches second end
MRC:
A measurement of the longest dimension of the shaft projection of an item,in distinction from width.CWCS
Length Of Shaft From Housing:
7.688 inches first end
MRC:
The nominal center to center distance between the mounting facilities parallel to the length.CWDT
Center To Center Distance Between Mounting Facilities Parallel To Length:
13.250 inches
MRC:
The temperature at which the item is designed to operate.CWDY
Tempurature Rating:
75.0 ambient degrees celsius and 40.0 operating degrees celsius
MRC:
The speed rating of a rotor,expressed in revolutions per minute.CWFX
Rotor Speed Rating In Rpm:
1800.0 single full load
MRC:
The nominal center to center distance between the mounting facilities parallel to the width.CWFY
Center To Center Distance Between Mounting Facilities Parallel To Width:
23.250 inches
MRC:
The amount of current for which an item is rated,expressed in amperes.CWGL
Current Rating In Amps:
222.000 single input
MRC:
Indicates the type of connection,rating sequence,and voltage rating at which the item is designed to operate,expressed in volts.CWGQ
Connection Type And Voltage Rating In Volts:
115.0 line to neutral single input
MRC:
The specification,standard,drawing,or similar instrument that specifies environmental and performance requirements or test conditions under which an item is tested and establishes acceptable limits within which the item must conform identified by an alphabetic and/or numeric reference number. includes the commercial and government entity (cage) code of the entity controlling the instrument.TEST
Test Data Document:
81349-mil-m-17413 specification (includes engineering type bulletins, brochures, etc., that reflect specification type data in specification format; excludes commercial catalogs, industry directories, and similar trade publications, reflecting general type data on certain environmental and performance requirements and test conditions that are shown as "typical", "average", "", etc.).