부품 정보
Fiber glass reinforcement not acceptable. End reinforcement shall be not less than 10.0 in. Lg and shall consist of not less than two flies and the end capped w/tube compound. Require three double wrap hose clamps. Gasket shall be tube compound w/characteristics required by military standard 27030
TXT
묘사:
Nonmetallic Hose Assembly
MRC:
The style designation indicating the configuration that most nearly corresponds to the cross-sectional shape of the item.AAGR
Cross Sectional Shape:
Round
MRC:
The length of a straight line which passes through the center of a circular figure or body,and terminates at the inside circumference.AARX
Inside Diameter:
6.000 inches
MRC:
The length of a straight line which passes through the center of a circular figure or body,and terminates at the outside circumference.ABKV
Outside Diameter:
6.750 inches
MRC:
The specification or standard /industrial or governmental/ that specifically covers one complete end fitting.ADLG
First End Fitting Specification/std Data:
Mil ms27025-21 standard (includes industry or association standards, individual manufactureer standards, etc.).
MRC:
The specification or standard /industrial or governmental/ that specifically covers one complete end fitting.ADLH
Second End Fitting Specification/std Data:
Mil ms27021-21 standard (includes industry or association standards, individual manufactureer standards, etc.).
MRC:
The industrial designation or term for the size of the quick disconnect internal or external end.ADLP
Quick Disconnect Size:
6.000 inches 1st end
MRC:
The industrial designation or term for the size of the quick disconnect internal or external end.ADLP
Quick Disconnect Size:
6.000 inches 2nd end
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the connection.AHNC
Connection Style:
Cam or lever (internal) 1st end
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the connection.AHNC
Connection Style:
Cam or lever (external) 2nd end
MRC:
The physical configuration of the outside of the end connection.AKUU
End Connection Design:
Straight 1st end
MRC:
The physical configuration of the outside of the end connection.AKUU
End Connection Design:
Straight 2nd end
MRC:
The name of the fitting and/or component and the element, compound, or mixture of which it is fabricated.AKXL
End Fitting Component And Material:
Complete fitting aluminum alloy all ends
MRC:
The name of the fitting and/or component and the plating, dip and/or coatingthat cannot be wiped off. plating and/or coating is any chemical and/or metallic additive, electrochemical or mild mechanical process which protects the surface.AKXM
Fitting Component And Surface Treatment:
Complete fitting anodize 1st end
MRC:
Indicates the type of connection/s/.AWLS
Connection Type:
External quick disconnect 2nd end
MRC:
Indicates the type of connection/s/.AWLS
Connection Type:
Internal quick disconnect 1st end
MRC:
Those features,not otherwise specified,which may be required for proper functioning of the item.CBBL
Features Provided:
Electrostatic discharge capability
MRC:
Indicates whether or not the second end is identical to the first end.CQBB
Second End Relationship With First End:
Not identical
MRC:
The minimum internal pressure rating,determined by destruction tests,at which the item can be expected to rupture.CQBD
Burst Test Pressure:
400.0 pounds per square inch
MRC:
An indication of whether or not the end has the capability to rotate.CQBG
First End Swivel Action Capability:
Not included
MRC:
The material and formation identifying the structural characteristic/s/ of the item and location.CQCS
Layer Composition And Location:
Outer layer wrapped rubber, chloroprene err-100
MRC:
The maximum pressure at which the item is rated for operation.CQGM
Maximum Operating Pressure:
125.0 pounds per square inch
MRC:
A steady,uniform,internal,static pressure that the item must withstand without leakage,abnormal distortion,or damage.CRDW
Hydrostatic Test Pressure:
200.0 pounds per square inch
MRC:
The type of protection provided by the outer covering.CRJM
Outer Covering Environmental Protection:
Oil resistant and ozone resistant and fuel resistant
MRC:
The condition of the item with respect to the texture of the inner surface.CRWL
Inside Surface Condition:
Smooth
MRC:
The means used and the measurement of the longest dimension of an item.CRXX
Measuring Method And Length:
600.000 inches
MRC:
An indication of whether or not the end has the capability to rotate.CRZY
Second End Swivel Action Capability:
Not included
MRC:
Markings included on an item for the purpose of offering instructions or warnings or to indicate the purpose,function,or application of the item.excludes manufacturers part numbers,symbols,or the like.MARK
Special Markings:
Hose, petroleum fuel, discharge 125 psi maximum working pressure
MRC:
The document designator of the specification or standard which established the item of supply.ZZZK
Specification Data:
81349-mil-h-82127 government specification
MRC:
The number,letter,or symbol that indicates the type,style,grade,class,and the like,of an item in a nonidentifying specification or standard.ZZZT
Specification Or Standard:
6-in. Size
MRC:
The technical differentiating characteristic/s/ of an item of supply which depart/s/ from the text of a specification or a standard in that it represents a selection of characteristics stated in the specification or standard as being optional,or a variation from one or more of the stated characteristics,or an additional characteristic not stated in the specification or standard.ZZZW
Departure From Cited Document:
As modified by o-a lg and special features