부품 정보
Arrester spark in accordance w/mil-a-54003, heater may be converted to an oil burning space heater by removing grate assembly and inserting the oil burner covered by mil-b-2029
MRC:
Indicates the type of mount utilized to support the item.AAXX
Mounting Type:
Floor surface, free standing, nonducted
MRC:
Indicates the heat medium type for which the unit is designed.ABAM
Heat Medium Type:
Air
MRC:
The length of a straight line which passes through the center of a circular figure or body,and terminates at the circumference.ABMZ
Diameter:
18.625 inches
MRC:
Indicates the type of device which controls the operation of the item.ALYC
Operating Control Type:
Any acceptable
MRC:
Indicates the type of heating element provided.BDXJ
Heating Element Type:
Combustion chamber
MRC:
The means used for purposes of igniting.BLJC
Ignition Method:
Manual
MRC:
The amount of fuel the item is rated to consume per hour.CQTY
Fuel Consumption Rate Per Hour:
Not rated
MRC:
The rate of heat delivery of the item.CQXD
Heat Delivery Rate:
45000.0 british thermal unit
MRC:
The means by which the fuel is fed to the item.CSGC
Fuel Feed Method:
Manual
MRC:
Indicates the type of fuel(s) for which the item is designed.FUEL
Fuel Type:
Solid fuel
MRC:
A measurement from the bottom to the top of an object,in distinction from depth.HGTH
Height:
18.625 inches
MRC:
The number,letter,or symbol that indicates the type,style,grade,class,and the like,of an item in a nonidentifying specification or standard.ZZZT
Specification Or Standard:
1 type
MRC:
The variation when the item is in conformity with a type designator covered by a specification or standard,except in regard to one or more technical differentiating characteristics.ZZZX
Departure From Cited Designator:
As modified by special features