TXT
묘사:
Gasoline Engine Generator Set
MRC:
The cooling medium used to maintain the required operating temperature of the prime mover.AAXS
Prime Mover Cooling Medium:
Air
MRC:
Indicates the type of mount utilized to support the item.AAXX
Mounting Type:
Wheel
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
75.750 inches
MRC:
The distance measured in a straight line from the bottom to the top of an item.ABKW
Overall Height:
48.000 inches
MRC:
An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
Overall Width:
48.500 inches
MRC:
Indicates the type of current whether alternating,direct,or both.ACDC
Current Type:
Ac
MRC:
The direct current rating for which the item is rated,expressed in amperes.ACUT
Direct Current Rating In Amps:
300.0
MRC:
The value,or range of values,of direct current potential for which the item is rated.ACYR
Dc Voltage Rating:
28.0 volts
MRC:
The number of complete cyclic changes,per unit of time,for which an item is rated.ACZB
Frequency Rating:
400.0 hertz
MRC:
Indicates the type of document by the title.AJJZ
Document Type:
Technical order
MRC:
The number or symbol used to identify the document.AJKA
Document Identification:
No. 35c2-3-11-1, -3 and -4
MRC:
Indicates the type of inclosure provided to coat,cover,protect,or encase the item.AKNA
Inclosure Type:
Fully enclosed
MRC:
An identifying number assigned by the government agency or commercial organization controlling the item.AMSB
Identifying Number:
A1 type no. And e30 type no.
MRC:
An indication of whether or not winterization is included.AMWJ
Winterization Feature:
Included
MRC:
The name of the manufacturer.AQGA
Manufacturer Name:
Westinghouse electric corp
MRC:
The alternating current for which the item is rated,expressed in watts.AYGY
Ac Wattage Rating:
30.0 kilowatts
MRC:
The direct current for which the item is rated,expressed in watts.AYHA
Dc Wattage Rating:
7.5 kilowatts
MRC:
The total electrical line to line voltage for which the item is rated,expressed in volts.AYHB
Line To Line Voltage In Volts:
200.0
MRC:
The total electrical line to neutral voltage for which the item is rated,expressed in volts.AYHC
Line To Neutral Voltage In Volts:
115.0
MRC:
The ratio between actual rated power,and power required by a specified load applied to the item,expressed in percent.AYHD
Power Factor In Percent:
0.8
MRC:
Indicates the type of excitor provided.AYHE
Excitor Type:
Self-excited
MRC:
An indication of whether or not an excitor is included.AYHF
Excitor:
Not included
MRC:
The means used to start the prime mover.AYQZ
Prime Mover Starting Method:
Electric motor
MRC:
An indication of whether or not an automatic starting feature is provided.AZBM
Automatic Starting Feature:
Not provided
MRC:
The name of the manufacturer of the prime mover.AZBN
Prime Mover Manufacturer Name:
Any acceptable
MRC:
Indicates the type of housing provided.AZCB
Housing Type:
Inclosed
MRC:
The ambient temperature of the medium surrounding an item at which it can be operated,expressed in degrees celsius.AZCL
Ambient Tempurature In Deg Celsius:
-54.0 and 55.0
MRC:
An indication of whether or not radio interference suppression is included.AZKT
Radio Interference Suppression:
Included
MRC:
The name of the government agency,commercial organization,or other source,which controls the document.BBJC
Document Controlling Agency:
Usaf
MRC:
The number of alternating current phases.FAAZ
Phase:
Three