TXT
묘사:
Reciprocating Compressor Unit
MRC:
The number of compressors incorporated in the unit.AAXG
Compressor Quantity:
1
MRC:
The percentage of time for which the item is designed to generate without degradation of rated capacity and discharge pressure.AAXJ
Duty Cycle In Percent:
100
MRC:
The media the machine is designed to compress.AAXK
Gas For Which Designed:
Air
MRC:
The rated capacity of gas delivered by the last stage of compression.AAXL
Discharge Flow Rate:
15.000 cubic feet per minute
MRC:
The gage pressure of gas delivered by the last stage of compression. referred to as condensing pressure for refrigeration compressors.AAXM
Discharge Pressure:
3500.000 pounds per square inch gage
MRC:
The design of the system necessary to maintain the required operating temperature of an item and discharge temperature of the compressed gases.AAXP
Cooling System Design:
Single
MRC:
The cooling medium used to maintain the required operating temperature of the compressed gases.AAXQ
Compressed Gas Cooling Medium:
Air
MRC:
The cooling medium used to maintain the required operating temperature of the compressor.AAXR
Compressor Cooling Medium:
Air
MRC:
The cooling medium used to maintain the required operating temperature of the prime mover.AAXS
Prime Mover Cooling Medium:
Air
MRC:
The position of the gas cooling equipment whether between stages /intercooler/,after the last stage /aftercooler/,or both.AAXU
Gas Cooling Equipment Type:
Air type aftercooler and air type intercooler
MRC:
The method by which a no load condition is obtained for starting the item.AAXV
Unloader Type:
Automatic
MRC:
Indicates the type of mount utilized to support the item.AAXX
Mounting Type:
Wheel
MRC:
The reciprocating compressor design as determined by the mechanical action by which compression takes place in the cylinder/s/ of the compressor.AAXY
Reciprocating Compressor Design:
Single acting
MRC:
The number of intake connections included on the item.AAYT
Intake Connection Quantity:
1
MRC:
Indicates the type of prime mover included with the unit.AKDJ
Prime Mover Type:
Electric motor
MRC:
Indicates the type of control device provided.BDML
Control Device Type:
Automatic start-stop and constant speed
MRC:
Indicates the type of safety device(s) provided.BPRZ
Safety Device Type:
Relief valve
MRC:
Those features,not otherwise specified,which may be required for proper functioning of the item.CBBL
Features Provided:
Fungus resistant treatment
MRC:
Indicates the type and amount of electrical flow at which the item is designed to operate,expressed in amperes.CQJY
Current Type And Rating In Amps:
20.0 ac and 40.0 ac
MRC:
The total electrical voltage,expressed in volts,and the type of current whether alternating or direct.CSBH
Voltage In Volts And Current Type:
208.0 ac or 416.0 ac
MRC:
The number of alternating current phases.FAAZ
Phase:
Three
MRC:
The cycles per second /hertz/ of the alternating current.FREQ
Frequency In Hertz:
60.0
MRC:
The number,letter,or symbol that indicates the type,style,grade,class,and the like,of an item in a nonidentifying specification or standard.ZZZT
Specification Or Standard:
2 type and 2 class