TXT
묘사:
Fluid Cooler Core Assembly
MRC:
A measurement of the longest dimension of the core,in distinction from width.AKMJ
Core Length:
17.938 inches
MRC:
A measurement taken at right angles to the length of the core,in distinction from thickness.AKMK
Core Width:
5.563 inches
MRC:
The number of tubes included on the item.ARNF
Tube Quantity:
48
MRC:
A measurement from the bottom to the top of the core,in distinction from depth.ARPN
Core Height:
Between 7.432 inches and 7.442 inches
MRC:
The means by which the tube/s/ is attached.AWMZ
Tube Attachment Method:
Brazed both ends
MRC:
A measurement of the surface of the item that effects the transfer of heat.CTRC
Effective Heat Transfer Surface Area:
12.95 square feet
MRC:
The chemical compound or mechanical mixture properties of which the item is fabricated.MATT
Material:
Copper alloy tubes
MRC:
The specification,standard,or manufacturers reference,and the classification designation,such as class,condition,temper,and the like,that identifies the material.MDCL
Material Specification:
Mil-c-15726, comp 70-30 military specification single material response tubes
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the item.STYL
Style Designator:
Strut, rectangular
MRC:
The number,letter,or symbol that indicates the type,style,grade,class,and the like,of an item in a nonidentifying specification or standard.ZZZT
Specification Or Standard:
B type