부품 번호:
mil-i-631typefformtsgracl1
TXT
묘사:
Electrical Insulation Sleeving
MRC:
A measurement of the smallest dimension of the wall,in distinction from length or width.AAGT
Wall Thickness:
Between 0.019 inches and 0.019 inches
MRC:
An indication that the level of probability that an item will operate without failure,at a specified rated capability,at a specified temperature,and for a specified period of time,has been established by testing random samples of production lot.AARG
Reliability Indicator:
Not established
MRC:
The length of a straight line which passes through the center of a circular figure or body,and terminates at the inside circumference.AARX
Inside Diameter:
Between 0.064 inches and 0.072 inches
MRC:
A value which expresses the degree of heat or cold as applied to the operation,or limitation of operation,of an item.ABJH
Tempurature Rating:
-30.0 degrees celsius and 75.0 degrees celsius
MRC:
The environmental elements or conditions that an item is designed or protected to resist or withstand satisfactorily.ADZC
Environmental Protection:
Flame resistant and mildew resistant and oil resistant
MRC:
The maximum rated load in tension applied in a longitudinal direction,per unit of cross-sectional area,that the material can withstand without rupture.CQBC
Min. Tensile Strength (psi):
1800 pounds per square inch
MRC:
Flexible,capable of being bent,turned or twisted,within limits,without breaking,or rigid,resisting change of form,inflexible.FLEX
Flexibility:
Flexible
MRC:
The element,compound,or mixture of which an item is fabricated,excluding any surface treatment.MATL
Material:
Plastic, polyvinyl chloride, mil-i-631, type f, form u, grade a, class 1, category 1
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the item.STYL
Style Designator:
Nonshrinkable