TXT
묘사:
Electric Heat Treating Furnace
MRC:
The length of a straight line which passes through the center of a circular figure or body,and terminates at the inside circumference.AARX
Inside Diameter:
60.000 inches
MRC:
Indicates the type of mount utilized to support the item.AAXX
Mounting Type:
Floor
MRC:
Indicates the type of current whether alternating,direct,or both.ACDC
Current Type:
Ac
MRC:
The number of complete cyclic changes,per unit of time,for which an item is rated.ACZB
Frequency Rating:
60.0 hertz
MRC:
The maximum temperature at which the item is rated to operate for an extended period of time.AEHZ
Maximum Operating Temp:
1750.0 degrees fahrenheit
MRC:
An inside measurement between specified points of an item,in distinction from height.AFEF
Inside Depth:
105.000 inches
MRC:
The minimum and maximum limits of temperature at which the item is rated for operation.AFGA
Operating Tempurature Range:
+600.0/+1750.0 degrees fahrenheit
MRC:
The name and number of parts supplied with the item which may be required for application.AKYD
Accessory Components And Quantity:
Speedomax h temp control panel
MRC:
Indicates the design type of the item.APGF
Design Type:
Convection pit
MRC:
Indicates the type of temperature control device provided.AZFX
Tempurature Control Device Type:
Automatic
MRC:
The rated power that an item can safely consume or provide,measured in kilowatts.CFSP
Wattage Rating In Kilowatts:
48.0
MRC:
An indication of whether or not a tilting hearth is included.CFSQ
Tilting Hearth:
Not included
MRC:
An indication of whether or not a work holding basket is included.CFSR
Work Holding Basket:
Not included
MRC:
Indicates the location and number of doors and/or openings.CFSS
Door/opening Location And Quantity:
Opening in top 1
MRC:
An indication of whether or not a counterweight(s) is included.CFST
Counterweight:
Not included
MRC:
An indication of whether or not equipment for a flame curtain is included.CFSW
Equipment For Flame Curtain:
Not included
MRC:
The means used to operate the access.CGSP
Access Operation Method:
Manually operated cover
MRC:
The total electrical voltage.ELEC
Voltage In Volts:
460.0
MRC:
The number of alternating current phases.FAAZ
Phase:
Three
MRC:
The number,letter,or symbol that indicates the type,style,grade,class,and the like,of an item in a nonidentifying specification or standard.ZZZT
Specification Or Standard:
3 class