TXT
묘사:
Electrolytic Fixed Capacitor
MRC:
An indication that the level of probability that an item will operate without failure,at a specified rated capability,at a specified temperature,and for a specified period of time,has been established by testing random samples of production lot.AARG
Reliability Indicator:
Established
MRC:
The rate of failure determined under specified conditions to establish the reliability of an item,expressed in percent.AARH
Reliability Failure Rate Level In Percent:
0.0001
MRC:
A designator indicating a graphic representation,in standard and accepted symbols,of essential electrical-electronic elements and related connections on the item.AEBZ
Schematic Diagram Designator:
No common or grounded electrodes, w/separate case terminal
MRC:
The relative level of the quantity of electric charge at a given potential which the capacitor is capable of receiving and storing per section.CQBQ
Capacitance Value Per Section:
25.000 microfarads single section
MRC:
The temperature/s/ at which an item can function without voltage derating.CQJJ
Nonderated Operating Temp:
Between -55.0 degrees celsius and 85.0 degrees celsius
MRC:
Stray direct current of relatively small value which flows through the item when voltage is impressed across it,measured at maximum operating temperature.CQLH
Dc Leakage At Maximum Operating Temp:
1.000 microamperes
MRC:
The highest value and type of potential that may be continuously applied to the item per section at the highest operating temperature permissible without voltage derating.CQWM
Nonderated Continuous Voltage Rating And Type Per Section:
8.0 dc single section
MRC:
The chemical compound or mechanical mixture properties of which the case is fabricated.CWJK
Case Material:
Glass
MRC:
The chemical compound or mechanical mixture properties of which the capacitive electrode is fabricated.CWNJ
Capacitive Electrode Material:
Tantalum
MRC:
Stray direct current of relatively small value flows through the capacitor when voltage is impressed across it,measured at reference temperature.CWQH
Dc Leakage At Reference Temp:
1.000 microamperes
MRC:
The reference temperature at which a rating is established.CWQQ
Reference Tempurature At Which Rated:
25.0 degrees celsius
MRC:
The document designator of the specification or standard which established the item of supply.ZZZK
Specification Data:
81349-mil-c-39006/22d government specification