측정 단위:
* special requirements. FT
TXT
묘사:
Radio Frequency Cable
MRC:
The style designation indicating the configuration that most nearly corresponds to the cross-sectional shape of the item.AAGR
Cross Sectional Shape:
Round
MRC:
A measure of the opposition to the flow of electrical current.AAPP
Electrical Resistance:
50.0 ohms impedance
MRC:
The length of a straight line which passes through the center of a cross section,and terminates at the outside circumference.ADVL
Cross Section Outside Diameter:
0.212 inches
MRC:
The number of electrical conductors included on the item.AMQN
Conductor Quantity:
1
MRC:
The property of a system of conductors and dielectrics which permits the storage of electricity when potential difference exists between the conductors,expressed in picofarads.AXGH
Capacitance In Picofarads:
30.8 per foot
MRC:
The fabricated form of the conductor.CXCW
Conductor Form:
Stranded single conductor
MRC:
The arrangement and number of arrangements of the conductors.CXDQ
Conductor Arrangement And Quantity:
1 coaxial
MRC:
The maximum sustained voltage that can be safely applied to the item without risking failure or damage.CXFK
Voltage Rating:
1400.0 root mean square (rms) operating voltage single conductor
MRC:
The chemical compound or mechanical mixture properties of which the item is fabricated.MATT
Material:
Copper core conductor single conductor
MRC:
The specification,standard,or manufacturers reference,and the classification designation,such as class,condition,temper,and the like,that identifies the material.MDCL
Material Specification:
Astm b298 assn standard single material response core conductor single conductor
MRC:
An indication of the precious material and its location in the item.PMLC
Precious Material And Location:
Surface single conductor silver and surface shields braid silver
MRC:
Identification of the precious material contained in the item.PRMT
Precious Material:
Silver