MRC:
Indicates the type of mount utilized to support the item.AAXX
Mounting Type:
Floor or wall
MRC:
Indicates the type of current whether alternating,direct,or both.ACDC
Current Type:
Ac
MRC:
The number of complete cyclic changes,per unit of time,for which an item is rated.ACZB
Frequency Rating:
Between 50.0 hertz and 60.0 hertz
MRC:
Indicates the designed use of the item.ALCD
Usage Design:
Compressor, condenser fan, evaporator fan
MRC:
The value(s) of potential for which the item is rated.AMSE
Voltage Rating:
230.0 pounds per hour wet
MRC:
Indicates the type of cooling for which the condenser is designed.AZAD
Condenser Cooling Type:
Air
MRC:
Indicates the type of compressor unit for which the item is designed.AZSD
Compressor Unit Type:
Closed
MRC:
The metallic,nonmetallic,and/or chemical properties with which the item is plated,dipped,and/or coated.the treatment is designed to protect the surface(s) and cannot be wiped off.SFTT
Surface Treatment:
Enamel
MRC:
The number,letter,or symbol that indicates the type,style,grade,class,and the like,of an item in a nonidentifying specification or standard.ZZZT
Specification Or Standard:
1 type and b size and 1 class