부품 정보
Series 5000m power conversion module model 5600m
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
169.000 inches
MRC:
The distance measured in a straight line from the bottom to the top of an item.ABKW
Overall Height:
40.000 inches
MRC:
An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
Overall Width:
82.000 inches
MRC:
The ratio of permissible frequency deviation from the controlled constant value,expressed in percent.ANRQ
Frequency Regulation Percent:
0.06 single power output
MRC:
The input value/s/,or range of values,for which the item is rated.APNX
Input Voltage Rating:
380.0 dc volts single operating power rqmt
MRC:
The output value/s/,or range of values,for which the item is rated.APPA
Output Voltage Rating:
380.0 dc volts single power output
MRC:
The number of complete cyclic changes,per unit of time,for which the input is rated.APTQ
Input Frequency Rating:
50.0 hertz single operating power rqmt
MRC:
The number of complete cyclic changes,per unit of time,for which the output is rated.APTS
Output Frequency Rating:
50.0 hertz single power output
MRC:
The ambient temperature range at which the item is designed to operate.AYNH
Operating Ambient Tempurature Range:
+0.1/+40.0 degrees celsius
MRC:
The rated output power that an item can safely consume or provide,measured in watts.BGQR
Output Wattage Rating:
480.0 kilowatts single power output
MRC:
The output current rating at which the item is designed to operate.CWGH
Output Current Rating:
912.0 dc amperes single power output
MRC:
The amount of input current for which the item is rated.CWHM
Input Current Rating:
932.0 dc amperes single operating power rqmt
MRC:
The emergency operating time a battery power supply can deliver full rated output voltage/current before the output drops below a specified value.CXMX
Battery Power Supply Emergency Operating Time:
30.0 and 75.0
MRC:
Those unusual or unique characteristics or qualities of an item not covered in the other requirements and which are determined to be essential for identification.FEAT
Special Features:
Unit price present in management data segment is the base price for the ups unit and 15 minutes battery time, any additional battery time or ancillary equipment will cost extra; call the pccie office, sm-alc/liet, dsn 633-0901 for further details; battery breaker; mbb; 461d emi filter; 10 percent input harmonic filter; rs232 comm port; static switch failure alarm; alarm for secondary source; internal battery cycle monitor and programmable battery state ofhealth