MRC:
The number of scale divisions.ABWG
Scale Division Quantity:
44 single indicator 1st range
MRC:
The number of scale divisions.ABWG
Scale Division Quantity:
76 single indicator 2nd range
MRC:
The number of scale divisions.ABWG
Scale Division Quantity:
76 single indicator 3rd range
MRC:
The number of scale divisions.ABWG
Scale Division Quantity:
76 single indicator 4th range
MRC:
The number of scale divisions.ABWG
Scale Division Quantity:
76 single indicator 5th range
MRC:
The number of scale divisions.ABWG
Scale Division Quantity:
76 single indicator 6th range
MRC:
The number of scale divisions.ABWG
Scale Division Quantity:
76 single indicator 7th range
MRC:
The number of complete cyclic changes,per unit of time,for which an item is rated.ACZB
Frequency Rating:
50.000 hertz
MRC:
The name and number of those parts furnished with the item of supply that have not been specified elsewhere.AKYN
Furnished Items And Quantity:
Electric cord 1
MRC:
An indication of the accuracy of an item,expressed in percent.APPN
Accuracy In Percent:
-2.0/+2.0 at full scale single indicator all ranges
MRC:
The source of power which provides the energy required for the operation of the item.AWZJ
Power Source:
External
MRC:
The minimum to maximum value which the item is capable of measuring.BHMW
Measurement Range:
-5.0/+17.0 decibels above or below one milliwatt single indicator 1st range
MRC:
The minimum to maximum value which the item is capable of measuring.BHMW
Measurement Range:
+0.5/+5.0 millivolts, ac single indicator 2nd range
MRC:
The minimum to maximum value which the item is capable of measuring.BHMW
Measurement Range:
+0.5/+5.0 volts, ac single indicator 5th range
MRC:
The minimum to maximum value which the item is capable of measuring.BHMW
Measurement Range:
+5.0/+50.0 volts, ac single indicator 6th range
MRC:
The minimum to maximum value which the item is capable of measuring.BHMW
Measurement Range:
+5.0/+50.0 millivolts, ac single indicator 3rd range
MRC:
The minimum to maximum value which the item is capable of measuring.BHMW
Measurement Range:
+50.0/+500.0 millivolts, ac single indicator 4th range
MRC:
The minimum to maximum value which the item is capable of measuring.BHMW
Measurement Range:
+50.0/+500.0 volts, ac single indicator 7th range
MRC:
The means provided for selecting a scale.BLSB
Scale Selection Method:
Switch
MRC:
Those features,not otherwise specified,which may be required for proper functioning of the item.CBBL
Features Provided:
Portable
MRC:
The value(s) of root mean square or direct current potential which must be applied to the item for operation,expressed in volts.CTWN
Operating Voltage Rating In Volts:
117.0 ac
MRC:
The metallic,nonmetallic,and/or chemical properties with which the item is plated,dipped,and/or coated.the treatment is designed to protect the surface(s) and cannot be wiped off.SFTT
Surface Treatment:
Enamel