부품 정보
Auto-restart on microprocessor lock up; proportional temp cont; lge led temp display; platinum rtd temp sensor; temp recorder o/p jack; visual & audible alarms indi ov temp cond; temp can be maintained or automatically shutoff at end of timing cycle; 20 min rise time fm ambient to 200 degrees c; 7 min recovery time at 150 degrees c; microprocessor based timer settable in units of min or hr up to 99.9 hr; can display elapsed time or time remaining in timing period; timer can be started automatically when oven temp reaches set pt; audible end of time period alarm; stnls stl heater elements, blower, shelves, interior, plenums; enameled stl ext; 3 in. Insul - all sides; plug styl door w/1 pc silicone gasket; 4 perforated stls stl shelves - adj on 1.75 in. Centers; shelf supports & plenums removable for cleaning; no int fltr; adj 2 in. Fitting for introducing inert gas or filtered air
TXT
묘사:
Electric Thermal Drying Oven
MRC:
An overall measurement between specified points of an item,in distinction from height.ABFY
Overall Depth:
25.000 inches
MRC:
The distance measured in a straight line from the bottom to the top of an item.ABKW
Overall Height:
35.000 inches
MRC:
An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
Overall Width:
32.000 inches
MRC:
Indicates the type of current whether alternating,direct,or both.ACDC
Current Type:
Ac
MRC:
An inside measurement taken at right angles to the length of an item,in distinction from thickness.ADJT
Inside Width:
23.000 inches
MRC:
The maximum temperature at which the item is rated to operate for an extended period of time.AEHZ
Maximum Operating Temp:
300.0 degrees celsius
MRC:
An inside measurement between specified points of an item,in distinction from height.AFEF
Inside Depth:
18.000 inches
MRC:
An inside measurement from the bottom to the top of an item,in distinction from depth.AFMQ
Inside Height:
19.500 inches
MRC:
The means used to control the temperature of an item.BBWM
Tempurature Control Method:
Automatic
MRC:
The rated power that an item can safely consume or provide.BDWW
Wattage Rating:
3100.0 watts
MRC:
The means used to provide circulation.BHGT
Circulation Method:
Forced
MRC:
The number of cabinet doors provided.BJPB
Cabinet Door Quantity:
1
MRC:
The extent of work protection provided from the heat source.BLSN
Work Protection From Heat Source:
Complete
MRC:
The minimum and maximum limits of temperature at which the item is normally operated.BLSQ
Normal Operating Tempurature Range:
+275.0/+300.0 degrees celsius
MRC:
An indication of whether or not a double wall constructed cabinet is provided.BLSR
Cabinet Double Wall Construction:
Provided
MRC:
An indication of whether or not an insulated cabinet is provided.BLST
Insulated Cabinet:
Provided
MRC:
An indication of whether or not a cabinet exhaust vent is provided.BLSX
Cabinet Exhaust Vent:
Provided
MRC:
An indication of whether or not an adjustable opening is provided.BLSY
Adjustable Opening:
Provided
MRC:
An indication of whether or not a cabinet fresh air intake is provided.BLSZ
Cabinet Fresh Air Intake:
Provided
MRC:
An indication of whether or not a fresh air intake adjustable opening is provided.BLTB
Fresh Air Intake Adjustable Opening:
Not provided
MRC:
The total electrical voltage.ELEC
Voltage In Volts:
208.0
MRC:
The number of alternating current phases.FAAZ
Phase:
Single
MRC:
The cycles per second /hertz/ of the alternating current.FREQ
Frequency In Hertz:
60.0
MRC:
Describes the capabilities,intended use,and/or purpose for which the item is provided.FTLD
Functional Description:
The baking/curing oven shall prov the capability to remove either solvents or moisture for sgl-layer & multi-layer pcb or wiring boards & vent to the osd; the pcb will be fabricated primarily frm fr-4 glass epoxy, polymide or kapton matl; matl thk can vary fm 0.008 in. - 0.25 in; maximum of 50, 16 in. X 18 in. Panels to be baked; the baking/curing process will occur prior to drilling, exposure, press lamination but after developing
MRC:
Characteristics or qualities of an item,not covered in any other requirement,which are considered essential information for one or more functions excluding nsn assignment.SUPP
Supplementary Features:
Meets cl 100 room rqmt; maintains min. 275 deg. C porm 0.5 deg.