Directional Coupler
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
Between 3.360 inches and 3.400 inches
MRC:
The distance measured in a straight line from the bottom to the top of an item.ABKW
Overall Height:
0.530 inches
MRC:
An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
Overall Width:
Between 1.180 inches and 1.190 inches
MRC:
The number of complete cycle changes of radiated electromagnetic energy,per unit of time,for which an item is rated.ANKZ
Radio Frequency Rating:
Between 1.7 gigahertz and 26.5 gigahertz
MRC:
Indicates the design type of the item.APGF
Design Type:
Bidirectional
MRC:
Indicates the type of unit.APQB
Unit Type:
Transmission line
MRC:
The measured weight of an item unencumbered by packaging or packing material.AWJN
Unpackaged Unit Weight:
1.900 ounces
MRC:
The maximum to minimum voltage standing wave ratio at a specified frequency/ies/.BGPS
Voltage Standing Wave Ratio At Reference Frequency:
1.35 to 1 at 1.7 to 18 ghz; 1.45 to 1 at 18 to 26.5 ghz
MRC:
The amount of decrease in power,expressed in decibels.BGPX
Power Loss In Decibels:
0.8 and 1.2
MRC:
The nomenclature by which the terminal fitting is identified.BGPY
Terminal Fitting Name:
Sma male or female coupling
MRC:
An indication of the designed use of the terminal fitting.BGQC
Terminal Fitting Usage Design:
Main line and secondary line