MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the body.AAQL
Body Style:
Bushing mounted
MRC:
The length of a straight line which passes through the center of the body,and terminates at the circumference.ABPM
Body Diameter:
0.385 inches
MRC:
A measurement of the longest dimension of a bushing,in distinction from width.ABXD
Bushing Length:
0.295 inches
MRC:
A measurement of the longest dimension of the body,in distinction from width.ADAQ
Body Length:
1.150 inches
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the actuator.AFUQ
Actuator Style:
Round
MRC:
The length of a straight line which passes through the center of the actuator,and terminates at the circumference.AFUR
Actuator Diameter:
0.223 inches
Actuator Height:
0.295 inches
Actuator Free Position Height:
0.295 inches
MRC:
The maximum voltage rating at which the item is designed to operate in an alternating current and/or direct current circuit,expressed in volts.AFXE
Maximum Voltage Rating In Volts:
28.0 dc
MRC:
The national stock number or the identification information of the end equipment for which the item is a part.AGAV
End Application:
NSN1-05-501-4504
MRC:
Indicates the type of inclosure provided to coat,cover,protect,or encase the item.AKNA
Inclosure Type:
Hermetically sealed
MRC:
The means of attaching the item.AXGY
Mounting Method:
Flush
MRC:
The amount to which the actuating force must be reduced to permit the switch to become unactuated.CRRM
Switch Release Force:
4.0 ounces
MRC:
The amount of force required to actuate the switch.CSJN
Switch Actuating Force:
30.0 ounces
MRC:
The movement of the switch actuator.CXQQ
Actuator Movement:
0.005 differential inches and 0.010 pretravel inches and 0.060 overtravel inches
MRC:
The amount of current the contacts are rated to make or break at maximum rated voltage,with a specified load.CXQR
Contact Load Current Rating At Maximum Rated Voltage:
4.000 amperes resistive dc and 1.000 amperes inductive dc and 2.000 amperes lamp dc
MRC:
Indicates the type and number of terminals for providing electrical connection.TTQY
Terminal Type And Quantity:
3 wire lead