3pdt, 25 amp (resistive), hermetically sealed, 28 vdc coil, 3% failure rate, raised vertical flange mount, relay
TXT
묘사:
Electromagnetic Relay
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
1.718 inches
MRC:
The distance between the center of one mounting facility and the center of the adjacent mounting facility parallel to the length.ABKQ
Center To Center Distance Between Mounting Facilities Parallel To Length:
1.396 inches single mounting facility and 1.446 inches single mounting facility
MRC:
The distance between the center of one mounting facility and the center of the adjacent mounting facility parallel to the width.ABKR
Center To Center Distance Between Mounting Facilities Parallel To Width:
0.625 inches single mounting facility
MRC:
The distance measured in a straight line from the bottom to the top of an item.ABKW
Overall Height:
1.010 inches
MRC:
An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
Overall Width:
1.025 inches
MRC:
A measurement taken at right angles to the length of the mounting slot,in distinction from thickness.ABTD
Mounting Slot Width:
0.150 inches single mounting facility
MRC:
The number of individual /not electrically connected/ windings.AKDX
Winding Quantity:
1
MRC:
The purpose for which the item is designed.AKSL
Purpose For Which Designed:
General
MRC:
The number of coils included on the item.APCN
Coil Quantity:
1
MRC:
Indicates the type of duty provided.APNP
Duty Type:
Continuous
MRC:
The number and combination(s) of the basic contact forms,in the order of assemblage,which make up the switching structure of the pile-up main contacts.AYSC
Pile-up Main Contact Form Arrangement:
3c
MRC:
Those features,not otherwise specified,which may be required for proper functioning of the item.CBBL
Features Provided:
Coil voltage suppression
MRC:
The general configuration and relative position of the facilities provided for mounting the item.CQYJ
Mounting Facility Pattern:
Triangle single mounting facility
MRC:
The distance between the center of one mounting facility and the center of the adjacent mounting facility parallel to the altitude of an isosceles triangle.CSQJ
Center To Center Distance Between Mounting Facilities Parallel To The Altitude Of An Isosceles Triangle:
0.312 inches single mounting facility
MRC:
The amount and type of voltage required at designated temperature to be applied to the input or energizing element of the item to ensure normal operation of the switching elements.CSXF
Operating Voltage Rating And Type At Specificationified Temp:
13.5 volts dc 25 degrees celsius single winding
MRC:
The amount of current the main contacts are rated to make or break at maximum rated voltage,with a specified load.CTDL
Main Contact Load Current Rating At Maximum Rated Voltage:
25.0 amperes ac resistive load
MRC:
The amount of current the main contacts are rated to make or break at maximum rated voltage,with a specified load.CTDL
Main Contact Load Current Rating At Maximum Rated Voltage:
5.0 amperes ac lamp load
MRC:
The amount of current the main contacts are rated to make or break at maximum rated voltage,with a specified load.CTDL
Main Contact Load Current Rating At Maximum Rated Voltage:
10.0 amperes ac motor load
MRC:
The amount of current the main contacts are rated to make or break at maximum rated voltage,with a specified load.CTDL
Main Contact Load Current Rating At Maximum Rated Voltage:
12.0 amperes dc inductive load and 15.0 amperes ac inductive load
MRC:
The highest voltage at which the main contacts are rated for normal operation,expressed in volts.CWAB
Main Contact Maximum Voltage Rating In Volts:
115.0 ac and 28.0 dc
MRC:
Indicates the type and number of terminals for providing electrical connection.TTQY
Terminal Type And Quantity:
9 wire hook contacts