부품 정보
						Storage temp m40.0 to p85.0 degrees c;  humidi type 0-95 pct noncondensing;  altitude 2.6 pct total output power for each 1, 000 ft to a maximum operating altitude of 15, 000 ft. Non operating storage maximum altitude is 40k
					 
				 
						
			
			
										
					
						MRC:
						The number of input alternating current phase(s).ANPM
					 
					
						Input Phase:
					
					
						Single single operating power rqmt					
				 
							
					
						MRC:
						The input value/s/,or range of values,for which the item is rated.APNX
					 
					
						Input Voltage Rating:
					
					
						115.0 ac volts  single operating power rqmt and 230.0 ac volts  single operating power rqmt					
				 
							
					
						MRC:
						The output value/s/,or range of values,for which the item is rated.APPA
					 
					
						Output Voltage Rating:
					
					
						5.0 dc volts  single power output					
				 
							
					
						MRC:
						The number of complete cyclic changes,per unit of time,for which the input is rated.APTQ
					 
					
						Input Frequency Rating:
					
					
						47.0 hertz  single operating power rqmt and 500.0 hertz  single operating power rqmt					
				 
							
					
						MRC:
						The ambient temperature range at which the item is designed to operate.AYNH
					 
					
						Operating Ambient Tempurature Range:
					
					
						+0.0/+45.0 degrees celsius					
				 
							
					
						MRC:
						The rated output power that an item can safely consume or provide,measured in watts.BGQR
					 
					
						Output Wattage Rating:
					
					
						1200.0 watts  single power output and 1600.0 watts  single power output					
				 
							
					
						MRC:
						The output current rating at which the item is designed to operate.CWGH
					 
					
						Output Current Rating:
					
					
						30.0 dc amperes  single power output					
				 
							
					
						MRC:
						The maximum alternating current voltage variation which may be present on the direct current output voltage level.CWGZ
					 
					
						Ripple Voltage At Full Load:
					
					
						100.0 millivolts peak single power output					
				 
							
					
						MRC:
						Indicates the location of the output control(s).CWHC
					 
					
						Output Control Location:
					
					
						Front panel single power output