TXT
묘사:
Electrical Contact
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
1.115 inches
MRC:
A measurement of the longest dimension of the pin,in distinction from width.AKRS
Pin Length:
0.745 inches
MRC:
A measurement taken at right angles to the length of the pin,in distinction from thickness.AKRV
Pin Width:
0.022 inches
MRC:
The chemical compound or mechanical mixture properties of which the item is fabricated.MATT
Material:
Copper alloy contact
MRC:
The specification,standard,or manufacturers reference,and the classification designation,such as class,condition,temper,and the like,that identifies the material.MDCL
Material Specification:
Qq-c-533 federal specification single material response contact
MRC:
An indication of the precious material and its location in the item.PMLC
Precious Material And Location:
Contact plating gold
MRC:
An indication of the precious material contained in the item,and the amount per a measurement scale.PMWT
Precious Material And Weight:
0.005 gold grains, troy
MRC:
Identification of the precious material contained in the item.PRMT
Precious Material:
Gold
MRC:
The metallic,nonmetallic,and/or chemical properties with which the item is plated,dipped,and/or coated.the treatment is designed to protect the surface(s) and cannot be wiped off.SFTT
Surface Treatment:
Nickel contact and gold contact
MRC:
The specification,standard,or manufacturers reference,and the classification designation,such as type,class,grade,and the like,that identifies the surface treatment material.STDC
Surface Treatment Specification:
Qq-n-290, class 2 federal specification 1st treatment response contact and mil-g-45204, type ii, grade c, class 1 military specification 2nd treatment response contact
MRC:
The specification,standard,drawing,or similar instrument that specifies environmental and performance requirements or test conditions under which an item is tested and establishes acceptable limits within which the item must conform identified by an alphabetic and/or numeric reference number. includes the commercial and government entity (cage) code of the entity controlling the instrument.TEST
Test Data Document:
81349-mil-c-55302/32 specification (includes engineering type bulletins, brochures, etc., that reflect specification type data in specification format; excludes commercial catalogs, industry directories, and similar trade publications, reflecting general type data on certain environmental and performance requirements and test conditions that are shown as "typical", "average", "", etc.).
MRC:
Indicates the type and number of terminals for providing electrical connection.TTQY
Terminal Type And Quantity:
1 wire wrap axially at one end