MRC:
The distance measured in a straight line from the bottom to the top of an item.AAJT
Overall Height:
7.500 inches
MRC:
A measurement of the longest dimension of an item,in distinction from width.AAJU
Overall Length:
9.250 inches
MRC:
An overall measurement taken at right angles to the length of an item,in distinction from thickness.AAJV
Overall Width:
5.625 inches
MRC:
Indicates the type of current whether alternating,direct,or both.ACDC
Current Type:
Ac input
MRC:
An indication of the feature/s/ of the inclosure.ANPZ
Inclosure Feature:
Totally enclosed
MRC:
The means of attaching the item.AXGY
Mounting Method:
Fixed base
MRC:
The means of cooling used to maintain the required operating temperature of the item.BFMF
Cooling Method:
Nonventilated
MRC:
Indicates the torque rating,and its type.BKPH
Torque Rating And Type:
50.0 inch-pounds running
MRC:
The government or industrial specification or standard that defines the inclosure feature.BKPQ
Inclosure Specificationification:
Commercial
MRC:
Indicates the type of control field voltage and its rating,expressed in volts.BKPS
Control Field Voltage Type And Rating In Volts:
24.0 ac
MRC:
Those features,not otherwise specified,which may be required for proper functioning of the item.CBBL
Features Provided:
Horizontal mounting position
MRC:
A measurement of the longest dimension of the shaft projection of an item,in distinction from width.CWCS
Length Of Shaft From Housing:
0.625 inches second end
MRC:
A measurement of the longest dimension of the shaft projection of an item,in distinction from width.CWCS
Length Of Shaft From Housing:
0.625 inches first end
MRC:
The nominal center to center distance between the mounting facilities parallel to the length.CWDT
Center To Center Distance Between Mounting Facilities Parallel To Length:
4.876 inches
MRC:
The temperature at which the item is designed to operate.CWDY
Tempurature Rating:
-40.0 ambient degrees fahrenheit and 125.0 ambient degrees fahrenheit
MRC:
The nominal center to center distance between the mounting facilities parallel to the width.CWFY
Center To Center Distance Between Mounting Facilities Parallel To Width:
4.063 inches
MRC:
Indicates the type of connection,rating sequence,and voltage rating at which the item is designed to operate,expressed in volts.CWGQ
Connection Type And Voltage Rating In Volts:
120.0 line to neutral first multiple input or 208.0 line to neutral low input or 240.0 line to neutral high input
MRC:
The number of alternating current phases.FAAZ
Phase:
Single input
MRC:
The cycles per second /hertz/ of the alternating current.FREQ
Frequency In Hertz:
50.0 input or 60.0 input