TXT
묘사:
Electromagnetic Relay
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
Between 0.281 inches and 1.500 inches
MRC:
The distance measured in a straight line from the bottom to the top of an item.ABKW
Overall Height:
0.280 inches
MRC:
A measurement of the longest straight line across a circular cross-sectional plane.ADAV
Overall Diameter:
0.406 inches
MRC:
The environmental elements or conditions that an item is designed or protected to resist or withstand satisfactorily.ADZC
Environmental Protection:
Hermetic
MRC:
The number of individual /not electrically connected/ windings.AKDX
Winding Quantity:
2
MRC:
The number of coils included on the item.APCN
Coil Quantity:
2
MRC:
The measured opposition to the flow of direct current offered by the item winding.APNA
Winding Dc Resistance Rating:
61.0 ohms all windings
MRC:
Indicates the type of duty provided.APNP
Duty Type:
Continuous
MRC:
Indicates the type and number of facilities by which the item is mounted.AXHR
Mounting Facility Type And Quantity:
1 terminal single mounting facility
MRC:
Those features,not otherwise specified,which may be required for proper functioning of the item.CBBL
Features Provided:
Coil voltage suppression and latching contacts and polarized
MRC:
The designation that identifies the schematic diagram of the electrical configuration of the main nonpile-up contacts including the number of poles or forms.CRNG
Nonpile-up Main Contact Arrangement:
1 pole, double throw, both positions maintained
MRC:
The interval for which the item,by design,is purposely delayed between introduction of power into the energizing element and completion of travel of the contact carrier,and/or between interruption of the energizing power and return of the contact carrier to its normal de-energizing position.CRXH
Time Delay:
0.0015 seconds fixed operate time
MRC:
The amount and type of voltage required at designated temperature to be applied to the input or energizing element of the item to ensure normal operation of the switching elements.CSXF
Operating Voltage Rating And Type At Specificationified Temp:
5.8 volts ac 25 degrees celsius all windings
MRC:
The amount of current the main contacts are rated to make or break at maximum rated voltage,with a specified load.CTDL
Main Contact Load Current Rating At Maximum Rated Voltage:
0.5 amperes dc resistive load
MRC:
The highest voltage at which the main contacts are rated for normal operation,expressed in volts.CWAB
Main Contact Maximum Voltage Rating In Volts:
28.0 dc
MRC:
Indicates the type and number of terminals for providing electrical connection.TTQY
Terminal Type And Quantity:
7 wire lead all functions