MRC:
A numeric-alpha designator indicating the pitch diameter tolerance and an external or internal thread.AAJD
Thread Class:
2a 2nd mounting facility
MRC:
A measurement of the extent of threads,including incomplete threads,along a line parallel to the longitudinal axis.AASA
Thread Length:
0.292 inches 2nd mounting facility and 0.332 inches 2nd mounting facility
MRC:
The specific commercial rating which classes the item as to what degree the item will withstand environmental elements and/or hazardous locations.ABFE
Hazardous Locations/environmental Protection:
Explosion proof
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
1.416 inches
MRC:
The distance measured in a straight line from the bottom to the top of an item.ABKW
Overall Height:
0.867 inches
MRC:
An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
Overall Width:
0.725 inches
First Flat Length:
0.355 inches single actuator and 0.395 inches single actuator
Flat Height:
0.084 inches single actuator and 0.104 inches single actuator
MRC:
The length of a straight line which passes through the center of a shaft,and terminates at the circumference.ABWV
Shaft Diameter:
0.198 inches single actuator and 0.208 inches single actuator
MRC:
A measurement of the longest dimension of the shaft,in distinction from width.ABXF
Shaft Length:
0.687 inches single actuator
MRC:
The number of individual sections included in the item.AFBH
Individual Section Quantity:
1
MRC:
Indicates the type of device used to prevent physical movement of the item on its mounting surface.AFDC
Nonturn Device Type:
Flatted bushing at 3: 00 o'clockflatted bushing at 9: 00 o'clock
MRC:
The minimum and maximum limits of temperature at which the item is rated for operation.AFGA
Operating Tempurature Range:
-65.0/+85.0 degrees celsius
MRC:
The general configuration of the contacts of a switch that describes its basic switching structure.AJZE
Switch Contact Basic Design:
Nonpile-up symmetrical
MRC:
The number of poles included in the item.AKPX
Pole Quantity:
1 single section front
MRC:
The number of positions to which the item may be actuated to energize electrical circuits.AKPY
Throw Quantity:
2 single section rear
MRC:
The means of attaching the item.AXGY
Mounting Method:
Printed circuit 1st mounting facilitythreaded bushing 2nd mounting facility
MRC:
A designation that is used for the purpose of general identification of the thread.CQJX
Thread Size:
0.250 inches 2nd mounting facility
MRC:
The voltage for which the contacts are rated,expressed in volts.CQMK
Contact Voltage Rating In Volts:
115.0 ac at sea level28.0 dc at sea level
MRC:
Indicates the number of connections on a rotor segment that are front to rear surface connected.CQTH
Rotor Through Connection Quantity:
1 single section
MRC:
The number of positions to which the switch actuator may be indexed.CRJH
Switch Actuator Indexing Position Quantity:
2 single actuator
MRC:
Indicates the type of shaft included on the item.CRSJ
Shaft Type:
Round, flatted single actuator
MRC:
Indicates the type of terminal for providing electrical connection to the item.CSCF
Terminal Type:
Printed circuit
MRC:
An indication of the switching action by the contacts of the item.CSHW
Contact Switching Action:
Breaks before makes single section rear
MRC:
The increments of angular rotation that the switch actuator moves between adjacent index positions.CSLC
Switch Actuator Positioning Increment:
36.0 degrees single actuator
MRC:
The minimum and maximum amount of turning force required to rotate an actuator through the detent positions.CSMW
Detent Rotational Torque Range:
+5.000/+20.000 inch-ounces single actuator
MRC:
The amount of current that the contacts are rated to make or break with a specified load.CTHF
Contact Load Current Rating:
500.0 milliamperes resistive load ac at sea level250.0 milliamperes inductive load dc at sea level and 500.0 milliamperes resistive load dc at sea level
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the item.STYL
Style Designator:
Wafer, printed board, bushing mount
MRC:
The specification,standard,drawing,or similar instrument that specifies environmental and performance requirements or test conditions under which an item is tested and establishes acceptable limits within which the item must conform identified by an alphabetic and/or numeric reference number. includes the commercial and government entity (cage) code of the entity controlling the instrument.TEST
Test Data Document:
81349-mil-s-3786 specification (includes engineering type bulletins, brochures, etc., that reflect specification type data in specification format; excludes commercial catalogs, industry directories, and similar trade publications, reflecting general type data on certain environmental and performance requirements and test conditions that are shown as "typical", "average", "", etc.).
MRC:
A designation distinguishing one group of thread diameter-pitch combinations from another by the number of threads per measurement scale for a specific diameter.THSD
Thread Series Designator:
Unef 2nd mounting facility
MRC:
The document designator of the specification or standard which established the item of supply.ZZZK
Specification Data:
81349-mil-s-3786/39 government specification