Liquid Level Switch
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
3.250 inches
MRC:
An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
Overall Width:
3.680 inches
MRC:
The value,or range of values,of direct current potential for which the item is rated.ACYR
Dc Voltage Rating:
Between 18.0 volts and 30.0 volts
MRC:
The identifying numeric code of the originator that controls or manufactures the electrical connector receptacle.AEEE
Connector Manufacturer Code:
81349
MRC:
The name of the equipment the item is specifically designed to accommodate.AFJE
Specific Equipment Accommodated:
Ch53e helicopter
MRC:
The means by which the item is actuated.AFLW
Actuation Method:
Buoyancy
MRC:
The national stock number or the identification information of the end equipment for which the item is a part.AGAV
End Application:
Helicopter, ch-53a/d/e; helicopter, mh-53e; helicopter, ch-53a/d/e
MRC:
Indicates the type of electrical connection included on the item.AGBD
Electrical Connection Type:
Connector receptacle
MRC:
The specification,standard,or manufacturer's number or symbol used to identify the connector.AGBG
Connector Identification:
Mil-c-5015
MRC:
An indication of whether or not a facility/ies/ to accommodate a battery/ies/ is included.ALSF
Internal Battery Accommodation:
Not included
MRC:
The amount of current at maximum rated voltage for which the item is designed.APGW
Current Rating At Maximum Rated Voltage:
0.5 amperes resistive load
MRC:
The amount of voltage for which the item is designed to withstand at the maximum rated current.APGY
Voltage Rating At Maximum Rated Current:
28.0 volts
MRC:
The number of floats provided.AWAE
Float Quantity:
1
MRC:
The temperature at which the item operates.AWTN
Operating Tempurature Rating:
Between -65.0 degrees fahrenheit and 250.0 degrees fahrenheit
MRC:
The means of attaching the item.AXGY
Mounting Method:
Flange
MRC:
The installed position for which the item is designed.BBJX
Mounting Position:
Horizontal
MRC:
The maximum continuous current which must not be exceeded in order to avoid damage to the item.BJKC
Maximum Current Rating:
0.5 amperes resistive load
MRC:
The designation that identifies the schematic diagram of the contact arrangement.BJKD
Contact Arrangement:
Single throw, normally open, normally closed
MRC:
An indication of whether or not a relay is included.BJKG
Relay:
Not included
MRC:
Indicates the type of liquid(s) for which the item is designed.BJKH
Liquid Type For Which Designed:
Lubricating oil
MRC:
The distance of the effective travel of the float.BJKN
Float Effective Travel:
Any acceptable
MRC:
The mounting dimensions of the item.BJKP
Mounting Dimensions:
Mtd by four no. 10-32 nf-2b self-locking inserts, three of which are equally spaced 1.312 in. C to c and one 1.187 in. C to c with first insert
MRC:
A measurement of the longest dimension from the mounting surface to the end of the item,which is designed to be inserted into the tank.BJKQ
Tank Insertion Length:
2.500 inches
MRC:
The master requirement codes of those requirements which are technically critical by reason of tolerance,fit,performance,or other characteristics which affect identification of the item.CRTL
Criticality Code Justification:
Feat