부품 정보
Cable tested for watertightness, and hydrostatic tested.
TXT
묘사:
Radio Frequency Cable
MRC:
The style designation indicating the configuration that most nearly corresponds to the cross-sectional shape of the item.AAGR
Cross Sectional Shape:
Round
MRC:
A measure of the opposition to the flow of electrical current.AAPP
Electrical Resistance:
50.00 ohms impedance
MRC:
The length of a straight line which passes through the center of a cross section,and terminates at the outside circumference.ADVL
Cross Section Outside Diameter:
0.545 inches
MRC:
The number of electrical conductors included on the item.AMQN
Conductor Quantity:
2
MRC:
The property of a system of conductors and dielectrics which permits the storage of electricity when potential difference exists between the conductors,expressed in picofarads.AXGH
Capacitance In Picofarads:
32.2 per foot
MRC:
The fabricated form of the conductor.CXCW
Conductor Form:
Solid 1st conductor
MRC:
The maximum sustained voltage that can be safely applied to the item without risking failure or damage.CXFK
Voltage Rating:
8000.0 root mean square (rms) operating voltage all conductors
MRC:
The chemical compound or mechanical mixture properties of which the item is fabricated.MATT
Material:
Copper 1st position conductor second conductor
MRC:
The chemical compound or mechanical mixture properties of which the item is fabricated.MATT
Material:
Copper 2nd position conductor second conductor
MRC:
The chemical compound or mechanical mixture properties of which the item is fabricated.MATT
Material:
Copper core conductor single conductor
MRC:
The chemical compound or mechanical mixture properties of which the item is fabricated.MATT
Material:
Plastic cross-linked polyolefin 4th position jacket
MRC:
The chemical compound or mechanical mixture properties of which the item is fabricated.MATT
Material:
Plastic polyester 3rd position tape and aluminum 3rd position tape
MRC:
The chemical compound or mechanical mixture properties of which the item is fabricated.MATT
Material:
Plastic polyethylene core primary insulation single conductor
MRC:
The document designator of the specification or standard which established the item of supply.ZZZK
Specification Data:
81349-mil-dtl-17/192 government specification